Difference between revisions of "Spectrometer Optics 1pass"

From Hall A Wiki
Jump to: navigation, search
(Procedure with Sieve-slit)
(Delta Scan with Hydrogen Elastic)
Line 77: Line 77:
 
   </tr>
 
   </tr>
 
   <tr>
 
   <tr>
     <td>2.0</td>
+
     <td>1.9</td>
 
     <td>1.5478</td>  
 
     <td>1.5478</td>  
     <td>33.0</td>
+
     <td>43.7</td>
 
     <td>-4</td>
 
     <td>-4</td>
 
     <td>12</td>
 
     <td>12</td>
Line 85: Line 85:
 
   </tr>
 
   </tr>
 
   <tr>
 
   <tr>
     <td>2.0</td>
+
     <td>1.9</td>
 
     <td>1.518</td>  
 
     <td>1.518</td>  
     <td>33.0</td>
+
     <td>43.7</td>
 
     <td>-2</td>
 
     <td>-2</td>
 
     <td>12</td>
 
     <td>12</td>
Line 93: Line 93:
 
   </tr>
 
   </tr>
 
   <tr>
 
   <tr>
     <td>2.0</td>
+
     <td>1.9</td>
 
     <td>1.4882</td>  
 
     <td>1.4882</td>  
     <td>33.0</td>
+
     <td>43.7</td>
 
     <td>0</td>
 
     <td>0</td>
 
     <td>12</td>
 
     <td>12</td>
Line 101: Line 101:
 
   </tr>
 
   </tr>
 
   <tr>
 
   <tr>
     <td>2.0</td>
+
     <td>1.9</td>
 
     <td>1.4585</td>  
 
     <td>1.4585</td>  
     <td>33.0</td>
+
     <td>43.7</td>
 
     <td>+2</td>
 
     <td>+2</td>
 
     <td>12</td>
 
     <td>12</td>
Line 109: Line 109:
 
   </tr>
 
   </tr>
 
   <tr>
 
   <tr>
     <td>2.0</td>
+
     <td>1.9</td>
 
     <td>1.4287</td>  
 
     <td>1.4287</td>  
     <td>33.0</td>
+
     <td>43.7</td>
 
     <td>+4</td>
 
     <td>+4</td>
 
     <td>12</td>
 
     <td>12</td>
Line 117: Line 117:
 
   </tr>
 
   </tr>
 
</table>
 
</table>
 +
 
==== Elastic from Hydrogen ====
 
==== Elastic from Hydrogen ====
 
* Time estimate: 1-2 hours
 
* Time estimate: 1-2 hours

Revision as of 12:15, 17 March 2015

Procedure without Sieve-slit

  • Time estimate: 4 hours
* Take a run at the following kinematics without the sieve-slit collimator.
* Start with initial right HRS spectrometer tune with the SOS quad in place of right Q1.
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
* Rates assume 5 carbon foils, 5 mSr acceptance, and 8% delta acceptance.
* A GMp expert will check the data quality and decide, if the right HRS tune needs to be adjusted to change the size of the acceptance.
* This process will be repeated until the spectrometer tune is satisfactory.
Ebeam [GeV] P0 [GeV/c] θe [deg] Q2 [GeV2] W [GeV] Rate [Hz] at 20 μA minutes for 235k events at 20 μA
1.9 0.75 43.7 0.79 1.500 197 20

Procedure with Sieve-slit

  • Time estimate: 3 hours
* Trained personnel will be required to install the 1-inch tungsten sieve-slit collimator onto the front face of the HRS.
* Take a sieve slit run with the multi-foil carbon target for the inelastic kinematics in the table.
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
* Repeat the above with the beam position shifted so that you see a vertical shift by one row.
* Rates assume 5 carbon foils, only 25 out of 63 sieve holes have events (~ 0.265 mSr acceptance), and 8% delta acceptance.
Ebeam [GeV] P0 [GeV/c] θe [deg] Q2 [GeV2] W [GeV] Rate [Hz] at 20 μA minutes for 100k events at 20 μA
1.9 0.75 43.7 0.79 1.500 10 160

Delta Scan with Hydrogen Elastic

  • Time estimate: 1-2 hours
* Trained personnel will be required to remove the 1-inch lead sieve-slit collimator onto the front face of the HRS.
* Take a run with the 15 cm liquid hydrogen target for the elastic kinematics in the table.
* There will be a time lapse between settings until the right dipole reaches the desired momentum and is stable.
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
Ebeam (GeV) k' (GeV) θe (deg) ΔP (%) Rate [Hz] at 20 μA minutes for 10k events at 20 μA
1.9 1.5478 43.7 -4 12 14
1.9 1.518 43.7 -2 12 14
1.9 1.4882 43.7 0 12 14
1.9 1.4585 43.7 +2 12 14
1.9 1.4287 43.7 +4 12 14

Elastic from Hydrogen

  • Time estimate: 1-2 hours
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
* Elastic electron-proton measurement.  Assuming a 15 cm LH2 target, a spectrometer acceptance of 5 msr and elastic from Eric's rate program 
to compute the cross-section.
Ebeam (GeV) k' (GeV) θe (deg) Q2 (GeV2) Rate [Hz] at 20 μA minutes for 40k events at 20 μA
2.0 1.488 33.0 0.96 12 55