Difference between revisions of "Spectrometer Optics 1pass"
From Hall A Wiki
(→Procedure with Sieve-slit) |
(→Delta Scan with Hydrogen Elastic) |
||
Line 77: | Line 77: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td> | + | <td>1.9</td> |
<td>1.5478</td> | <td>1.5478</td> | ||
− | <td> | + | <td>43.7</td> |
<td>-4</td> | <td>-4</td> | ||
<td>12</td> | <td>12</td> | ||
Line 85: | Line 85: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td> | + | <td>1.9</td> |
<td>1.518</td> | <td>1.518</td> | ||
− | <td> | + | <td>43.7</td> |
<td>-2</td> | <td>-2</td> | ||
<td>12</td> | <td>12</td> | ||
Line 93: | Line 93: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td> | + | <td>1.9</td> |
<td>1.4882</td> | <td>1.4882</td> | ||
− | <td> | + | <td>43.7</td> |
<td>0</td> | <td>0</td> | ||
<td>12</td> | <td>12</td> | ||
Line 101: | Line 101: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td> | + | <td>1.9</td> |
<td>1.4585</td> | <td>1.4585</td> | ||
− | <td> | + | <td>43.7</td> |
<td>+2</td> | <td>+2</td> | ||
<td>12</td> | <td>12</td> | ||
Line 109: | Line 109: | ||
</tr> | </tr> | ||
<tr> | <tr> | ||
− | <td> | + | <td>1.9</td> |
<td>1.4287</td> | <td>1.4287</td> | ||
− | <td> | + | <td>43.7</td> |
<td>+4</td> | <td>+4</td> | ||
<td>12</td> | <td>12</td> | ||
Line 117: | Line 117: | ||
</tr> | </tr> | ||
</table> | </table> | ||
+ | |||
==== Elastic from Hydrogen ==== | ==== Elastic from Hydrogen ==== | ||
* Time estimate: 1-2 hours | * Time estimate: 1-2 hours |
Revision as of 12:15, 17 March 2015
Contents
Procedure without Sieve-slit
- Time estimate: 4 hours
* Take a run at the following kinematics without the sieve-slit collimator. * Start with initial right HRS spectrometer tune with the SOS quad in place of right Q1. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Rates assume 5 carbon foils, 5 mSr acceptance, and 8% delta acceptance. * A GMp expert will check the data quality and decide, if the right HRS tune needs to be adjusted to change the size of the acceptance. * This process will be repeated until the spectrometer tune is satisfactory.
Ebeam [GeV] | P0 [GeV/c] | θe [deg] | Q2 [GeV2] | W [GeV] | Rate [Hz] at 20 μA | minutes for 235k events at 20 μA |
1.9 | 0.75 | 43.7 | 0.79 | 1.500 | 197 | 20 |
Procedure with Sieve-slit
- Time estimate: 3 hours
* Trained personnel will be required to install the 1-inch tungsten sieve-slit collimator onto the front face of the HRS. * Take a sieve slit run with the multi-foil carbon target for the inelastic kinematics in the table. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Repeat the above with the beam position shifted so that you see a vertical shift by one row. * Rates assume 5 carbon foils, only 25 out of 63 sieve holes have events (~ 0.265 mSr acceptance), and 8% delta acceptance.
Ebeam [GeV] | P0 [GeV/c] | θe [deg] | Q2 [GeV2] | W [GeV] | Rate [Hz] at 20 μA | minutes for 100k events at 20 μA |
1.9 | 0.75 | 43.7 | 0.79 | 1.500 | 10 | 160 |
Delta Scan with Hydrogen Elastic
- Time estimate: 1-2 hours
* Trained personnel will be required to remove the 1-inch lead sieve-slit collimator onto the front face of the HRS. * Take a run with the 15 cm liquid hydrogen target for the elastic kinematics in the table. * There will be a time lapse between settings until the right dipole reaches the desired momentum and is stable. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
Ebeam (GeV) | k' (GeV) | θe (deg) | ΔP (%) | Rate [Hz] at 20 μA | minutes for 10k events at 20 μA |
1.9 | 1.5478 | 43.7 | -4 | 12 | 14 |
1.9 | 1.518 | 43.7 | -2 | 12 | 14 |
1.9 | 1.4882 | 43.7 | 0 | 12 | 14 |
1.9 | 1.4585 | 43.7 | +2 | 12 | 14 |
1.9 | 1.4287 | 43.7 | +4 | 12 | 14 |
Elastic from Hydrogen
- Time estimate: 1-2 hours
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Elastic electron-proton measurement. Assuming a 15 cm LH2 target, a spectrometer acceptance of 5 msr and elastic from Eric's rate program
to compute the cross-section.
Ebeam (GeV) | k' (GeV) | θe (deg) | Q2 (GeV2) | Rate [Hz] at 20 μA | minutes for 40k events at 20 μA |
2.0 | 1.488 | 33.0 | 0.96 | 12 | 55 |