Difference between revisions of "HRS Detector Calibrations"

From Hall A Wiki
Jump to: navigation, search
Line 11: Line 11:
 
   </tr>
 
   </tr>
 
   <tr>
 
   <tr>
     <td>7.3</td>
+
     <td>11.02</td>
     <td>2.918</td>  
+
     <td>1.0</td>  
     <td>22.8</td>
+
     <td>48.8</td>
 
     <td>None</td>
 
     <td>None</td>
     <td>Optics Carbon</td>
+
     <td>15 cm LH2</td>
     <td>1 mm x 1 mm</td>
+
     <td>2 mm x 2 mm</td>
 
     <td>20&mu;A</td>
 
     <td>20&mu;A</td>
 
     <td>S0&&S2m</td>
 
     <td>S0&&S2m</td>
 
   </tr>
 
   </tr>
* Use <sup>12</sup>C "white" spectra to get maximum coverage of planes, take 250K events.
+
* Use LH2 "white" spectra to get maximum coverage of planes, take 250K events.
 
</table>
 
</table>
 
<ol>
 
<ol>
 
<li> Check the timing and calibration constants (shower ADC gains, pedestals, timing offsets, pulse height corrections, attenuation lengths, efficiencies, position dependencies).
 
<li> Check the timing and calibration constants (shower ADC gains, pedestals, timing offsets, pulse height corrections, attenuation lengths, efficiencies, position dependencies).
<li> VDCs and Straw Chambers (Yang Wang)<br>
+
<li> VDCs and Straw Chambers <br>
 
     * Look at drift time spectra, is the shape reasonable?  in the right time range?<br>
 
     * Look at drift time spectra, is the shape reasonable?  in the right time range?<br>
 
     * Fit for new time-to-distance map<br>
 
     * Fit for new time-to-distance map<br>
 
     * Look at focal plane distributions.<br>
 
     * Look at focal plane distributions.<br>
 
     * Check fiducial tracking efficiency, is it > 95%, If not, then check TDC windows and tracking parameters.<br>
 
     * Check fiducial tracking efficiency, is it > 95%, If not, then check TDC windows and tracking parameters.<br>
<li> HRS Scintillators (Barak Schmookler) <br>
+
<li> HRS Scintillators <br>
 
     * Look at all channels, compare against standard histograms.<br>
 
     * Look at all channels, compare against standard histograms.<br>
 
     * Are any channels firing at high rate (possible light leak)?<br>
 
     * Are any channels firing at high rate (possible light leak)?<br>
 
<li> Gas Cherenkov (Barak Schmookler) <br>
 
<li> Gas Cherenkov (Barak Schmookler) <br>
 
     * Look at histograms (Npe vs. x, and Npe vs. Shower), compare with standard distributions, ideally there shoudl be no x dependence.<br>
 
     * Look at histograms (Npe vs. x, and Npe vs. Shower), compare with standard distributions, ideally there shoudl be no x dependence.<br>
<li> Electromagnetic calorimeters (Longwu Ou)<br>
+
<li> Electromagnetic calorimeters <br>
 
     * Make sure all ADC channels have signals.<br>
 
     * Make sure all ADC channels have signals.<br>
 
     * Calibrate with electrons.<br>
 
     * Calibrate with electrons.<br>
 
</ol>
 
</ol>
 
* After these steps, the detectors should be fairly well calibrated.
 
* After these steps, the detectors should be fairly well calibrated.

Revision as of 15:15, 31 January 2016

  • Use LH2 "white" spectra to get maximum coverage of planes, take 250K events.
Ebeam [GeV] P0 [GeV/c] θe [deg] Collimator Target Fast Raster
X x Y
Beam Current Trigger
11.02 1.0 48.8 None 15 cm LH2 2 mm x 2 mm 20μA S0&&S2m
  1. Check the timing and calibration constants (shower ADC gains, pedestals, timing offsets, pulse height corrections, attenuation lengths, efficiencies, position dependencies).
  2. VDCs and Straw Chambers
    * Look at drift time spectra, is the shape reasonable? in the right time range?
    * Fit for new time-to-distance map
    * Look at focal plane distributions.
    * Check fiducial tracking efficiency, is it > 95%, If not, then check TDC windows and tracking parameters.
  3. HRS Scintillators
    * Look at all channels, compare against standard histograms.
    * Are any channels firing at high rate (possible light leak)?
  4. Gas Cherenkov (Barak Schmookler)
    * Look at histograms (Npe vs. x, and Npe vs. Shower), compare with standard distributions, ideally there shoudl be no x dependence.
  5. Electromagnetic calorimeters
    * Make sure all ADC channels have signals.
    * Calibrate with electrons.
  • After these steps, the detectors should be fairly well calibrated.