Difference between revisions of "Winter 2016 calorimeter calibration (elastic)"

From Hall A Wiki
Jump to: navigation, search
 
(21 intermediate revisions by the same user not shown)
Line 1: Line 1:
 
Back to [[https://hallaweb.jlab.org/wiki/index.php/Run_Plan_%28DVCS3%29 Winter2016 DVCS run plan]]
 
Back to [[https://hallaweb.jlab.org/wiki/index.php/Run_Plan_%28DVCS3%29 Winter2016 DVCS run plan]]
 +
 +
 +
Need to remove the plastic shield. <br>
 +
Calorimeter-Target distance =6.2m<br>
 +
LH2 target, unrastered beam (which means beam current at less than 5 uA). <br>
 +
LHRS in positive polarity.<br>
 +
Open LHRS collimator<br>
 +
DAQ: DVCS config, trigger is S0+S2, autovalidation.<br>
 +
angle<SUB>LHRS</SUB>= 38.04 [deg]<br>
 +
momentum<SUB> LHRS</SUB>= 2.127 GeV<br>
 +
beam energy= 4.5 GeV<br>
 +
 +
We will take about 1 hour beam with three calorimeter angles: 26.5, 25 and 23.5 deg.
 +
  
  
Line 6: Line 20:
  
 
[[Image:Kine_elast_versus_e_angle.jpg| 1000 px]]
 
[[Image:Kine_elast_versus_e_angle.jpg| 1000 px]]
 +
 +
 +
We are going to move the calorimeter and leave the HRS fixed but  we could have done the contrary (see table below).
 +
 +
 +
<table border="1"  style="width:90%">
 +
<tr>
 +
<td>  p<SUB>HRS</SUB> [GeV]=2.217</td>
 +
<td> angle<SUB>LHRS</SUB> [deg]=36.80</td>
 +
<td> minutes to 500 evts per blocs at 10uA=12</td>
 +
<td> kp [GeV]=3.0</td>
 +
<td> Q<SUP>2</SUP>=2.7585</td>
 +
</tr>
 +
<tr>
 +
<td>  p<SUB>HRS</SUB> [GeV]=2.127</td>
 +
<td> angle<SUB>LHRS</SUB> [deg]=38.04</td>
 +
<td> minutes to 500 evts per blocs at 10uA=9</td>
 +
<td> kp [GeV]=3.1</td>
 +
<td> Q<SUP>2</SUP>=2.603</td>
 +
</tr>
 +
<tr>
 +
<td>  p<SUB>HRS</SUB> [GeV]=2.046</td>
 +
<td> angle<SUB>LHRS</SUB> [deg]=39.18</td>
 +
<td> minutes to 500 evts per blocs at 10uA=6.</td>
 +
<td> kp [GeV]=3.2</td>
 +
<td> Q<SUP>2</SUP>=2.464</td>
 +
</tr>
 +
</table>

Latest revision as of 11:07, 13 February 2016

Back to [Winter2016 DVCS run plan]


Need to remove the plastic shield.
Calorimeter-Target distance =6.2m
LH2 target, unrastered beam (which means beam current at less than 5 uA).
LHRS in positive polarity.
Open LHRS collimator
DAQ: DVCS config, trigger is S0+S2, autovalidation.
angleLHRS= 38.04 [deg]
momentum LHRS= 2.127 GeV
beam energy= 4.5 GeV

We will take about 1 hour beam with three calorimeter angles: 26.5, 25 and 23.5 deg.


Elastic kinematic 4.5.jpg


Kine elast versus e angle.jpg


We are going to move the calorimeter and leave the HRS fixed but we could have done the contrary (see table below).


pHRS [GeV]=2.217 angleLHRS [deg]=36.80 minutes to 500 evts per blocs at 10uA=12 kp [GeV]=3.0 Q2=2.7585
pHRS [GeV]=2.127 angleLHRS [deg]=38.04 minutes to 500 evts per blocs at 10uA=9 kp [GeV]=3.1 Q2=2.603
pHRS [GeV]=2.046 angleLHRS [deg]=39.18 minutes to 500 evts per blocs at 10uA=6. kp [GeV]=3.2 Q2=2.464