Difference between revisions of "Left S1 scintillators"

From Hall A Wiki
Jump to: navigation, search
(HV cable numbering)
(Patch Panel, ADC and TDC numbering)
 
Line 46: Line 46:
 
A6                    L6            3/23/21            4/25/5
 
A6                    L6            3/23/21            4/25/5
 
---------------------------------------------------------------------
 
---------------------------------------------------------------------
A7                    R1            3/23/24           4/25/8
+
A7                    R1            3/23/22           4/25/8
A8                    R2            3/23/25           4/25/9
+
A8                    R2            3/23/23           4/25/9
A9                    R3            3/23/26           4/25/10
+
A9                    R3            3/23/24           4/25/10
A10                    R4            3/23/27           4/25/11
+
A10                    R4            3/23/25           4/25/11
A11                    R5            3/23/28           4/25/12
+
A11                    R5            3/23/26           4/25/12
A12                    R6            3/23/29           4/25/13
+
A12                    R6            3/23/27           4/25/13
 
</pre>
 
</pre>

Latest revision as of 16:38, 19 October 2008

S1 Specifics

S1 Detector

  • six counters 0.5 cm x 30 cm x 36 cm
  • each counter viewed from both ends by 2" PMT Burle 8575
  • time resolution of 200 ps per plane

PMT

Burle Maximum HV : 2600 V


HV cable numbering

S2m Channel     HV Slot    HV Channel
======================================
L1                 1            0
L2                 1            1
L3                 1            2
L4                 1            3
L5                 1            4
L6                 1            5
--------------------------------------
R1                 1            6
R2                 1            7
R3                 1            8
R4                 1            9
R5                 1            10
R6                 1            11

Patch Panel, ADC and TDC numbering

For the delay cables, we use the Betty row A patch panel.

Patch Panel         S2m Cable         ADC                TDC
Channel                          ROC/Slot/Channel   ROC/Slot/Channel
---------------------------------------------------------------------
A1                     L1            3/23/16            4/25/0
A2                     L2            3/23/17            4/25/1
A3                     L3            3/23/18            4/25/2
A4                     L4            3/23/19            4/25/3
A5                     L5            3/23/20            4/25/4
A6                     L6            3/23/21            4/25/5
---------------------------------------------------------------------
A7                     R1            3/23/22            4/25/8
A8                     R2            3/23/23            4/25/9
A9                     R3            3/23/24            4/25/10
A10                    R4            3/23/25            4/25/11
A11                    R5            3/23/26            4/25/12
A12                    R6            3/23/27            4/25/13