== Live Time ==
 +
 +
 
*The computer dead-time (CDT) occurs during the process of writing the experimental data into computer disk.
 
*The computer dead-time (CDT) occurs during the process of writing the experimental data into computer disk.
 
*CODA stores each event by its trigger type separately and controls the recording rate by adjusting the pre-scale factor (PS).  
 
*CODA stores each event by its trigger type separately and controls the recording rate by adjusting the pre-scale factor (PS).  
Line 5: Line 9:
 
<math>LT = \frac{Ps*N_{stored}}{N_{triggered}}</math>
 
<math>LT = \frac{Ps*N_{stored}}{N_{triggered}}</math>
  
[[Image:Example.jpg]]
+
[[Media:csr_livetime_90_646.png]]

Latest revision as of 10:55, 18 July 2016

Live Time

  • The computer dead-time (CDT) occurs during the process of writing the experimental data into computer disk.
  • CODA stores each event by its trigger type separately and controls the recording rate by adjusting the pre-scale factor (PS).
  • Then the computer dead-time is defined by comparing the number of events stored in the computer (Ntrigger) and the number of pre-scaled raw trigger events (Ntrigger/PS), which is recorded independently in the scaler information:

<math>LT = \frac{Ps*N_{stored}}{N_{triggered}}</math>

Media:csr_livetime_90_646.png