Difference between revisions of "Fall 2016 calorimeter calibration (elastic)"

From Hall A Wiki
Jump to: navigation, search
Line 4: Line 4:
  
 
Need to remove the plastic shield. <br>
 
Need to remove the plastic shield. <br>
Calorimeter-Target distance =5.5m<br>
+
Calorimeter-Target distance =6.0m<br>
 
LH2 target, unrastered beam (which means beam current at less than 5 uA). <br>
 
LH2 target, unrastered beam (which means beam current at less than 5 uA). <br>
 
LHRS in positive polarity.<br>
 
LHRS in positive polarity.<br>
 
Open LHRS collimator<br>
 
Open LHRS collimator<br>
 
DAQ: DVCS config, trigger is S0+S2, autovalidation.<br>
 
DAQ: DVCS config, trigger is S0+S2, autovalidation.<br>
angle<SUB>LHRS</SUB>= 38.04 [deg]<br>
+
angle<SUB>LHRS</SUB>= 32.50 [deg]<br>
momentum<SUB> LHRS</SUB>= 2.127 GeV<br>
+
momentum<SUB> LHRS</SUB>= 3.0 GeV<br>
 
beam energy= 6.4 GeV<br>
 
beam energy= 6.4 GeV<br>
  
We will take about 1 hour beam with three calorimeter angles: 26.5, 25 and 23.5 deg.  
+
We will take about 1 hour beam with three calorimeter angles: 21.4, 22.7 and 24.0 deg.  
  
  
  
 
[[Image:Elastic_kinematic_4.5.jpg| 1000px]]
 
[[Image:Elastic_kinematic_4.5.jpg| 1000px]]

Revision as of 11:43, 20 September 2016

Back to [Run Plan DVCS 3 ]

This is in progress (09-20-16 contact J. Roche)

Need to remove the plastic shield.
Calorimeter-Target distance =6.0m
LH2 target, unrastered beam (which means beam current at less than 5 uA).
LHRS in positive polarity.
Open LHRS collimator
DAQ: DVCS config, trigger is S0+S2, autovalidation.
angleLHRS= 32.50 [deg]
momentum LHRS= 3.0 GeV
beam energy= 6.4 GeV

We will take about 1 hour beam with three calorimeter angles: 21.4, 22.7 and 24.0 deg.


Elastic kinematic 4.5.jpg