Difference between revisions of "Run Plan (DVCS3)"

From Hall A Wiki
Jump to: navigation, search
(Target Boiling)
 
(170 intermediate revisions by 3 users not shown)
Line 1: Line 1:
For the 12 GeV DVCS experiment, go to [[https://hallaweb.jlab.org/wiki/index.php/DVCS3 DVCS3 wiki ]].
+
For the 12 GeV DVCS experiment, go to [[https://hallaweb.jlab.org/wiki/index.php/DVCS3 DVCS3 wiki ]]. <br>
  
Assume:
 
<ul>
 
<li>longitudinally polarized beam
 
<li>max 20 uA but for short times when it can go higher
 
<li>7.3 GeV-4 pass and 5.5GeV-3Pass and possibly 9.10 GeV-5Pass later on
 
</ul>
 
  
== Commissioning/ Calibration ==
+
For the Fall of 2016 (FY2017), we plan on taking the kinematics 36_2, 36_3 and as many of the  60_* ones as we can.
=== Beam instruments ===
+
==== BPM/Raster checks/Beam centering ====
+
<ol>
+
<li> Send unrastered beam to the four corners of a 2*2 mm square around assumed (0,0) position (as defined by RAD reading in beam dump). At each position compare harps against BPMs reading.
+
<li> ''JR: How to decide on beam centering beyond the RAD readings in the beam dump? Do we need to even go further than that?''
+
<li>Check size raster using the spot++ tool. Pending target boiling studies result, we will use a 2*2 mm raster.<br>
+
  '' JR: Is it a matter to ask MCC for a 2*2 mm raster or does the info needs to go to them in a more "native" unit. Do we have a choice of frequency?''
+
</ol>
+
  
==== BCMs====
 
Use the procedure that is under .....<br>
 
Need: To insure that minimal beam lost in the machine can be measured, beam that would go up to about 100 uA. We also need to be the only hall receiving beam.<br>
 
''JR: Do we want to calibrate against the Unser monitor? Is the Unser operational? Do we know its calibration constant''
 
  
==== Moeller ====
+
[[Image:Fall2016.jpg | 1200px]]
The proposal goal calls for &Delta;P/P=1%.<br>
+
''JR: How often do we want to measure the polarization? ''
+
  
==== Compton ====
+
[[Fall 2016 optic plans]]
At this time, we are hoping  to be able to use the Compton asa beam quality monitor.
+
  
=== Luminosity ===
+
[[Fall 2016 calorimeter calibration (elastic)]]
====Target Boiling ====
+
Check that the Carbon target doesn't boil. In similar conditions check if th hydrogen target does boil.
+
  
====Deadtime check ====
+
<hr>
The plan is to have multiple trigger that would let us check the deadtime. The cabling of these is yet to be defined.<br>
+
<hr>
 
+
<hr>
=== HRS ===
+
<hr>
===Measure efficiencies  S2m, Cerenkov and wire chamber ===
+
 
+
=== Calorimeter ===
+
==== DC readings ====
+
=== Elastic Calibration ===
+
 
+
==Main DVCS kinematics==
+

Latest revision as of 16:58, 2 November 2016

For the 12 GeV DVCS experiment, go to [DVCS3 wiki ].


For the Fall of 2016 (FY2017), we plan on taking the kinematics 36_2, 36_3 and as many of the 60_* ones as we can.


Fall2016.jpg

Fall 2016 optic plans

Fall 2016 calorimeter calibration (elastic)