Difference between revisions of "BigBite Spectrometer"

From Hall A Wiki
Jump to: navigation, search
(Electron Package)
(Added BB survey report)
Line 23: Line 23:
 
== Position Survey ==
 
== Position Survey ==
  
=== Sept 18. 2008 ===
+
=== Sept 18, 2008 ===
  
 
''Notice'': Terminology used in this section follows conventions of Hall A Tech Notes [http://hallaweb.jlab.org/publications/Technotes/files/2002/02-012.pdf JLAB-TN-02-012]:
 
''Notice'': Terminology used in this section follows conventions of Hall A Tech Notes [http://hallaweb.jlab.org/publications/Technotes/files/2002/02-012.pdf JLAB-TN-02-012]:
Line 35: Line 35:
 
** Front Shielding Plate @Z=1.590m
 
** Front Shielding Plate @Z=1.590m
 
** At Beam Height, Edge of Bigbite Coil at Detector Side @Z=2.46m
 
** At Beam Height, Edge of Bigbite Coil at Detector Side @Z=2.46m
 +
 +
 +
=== Oct. 28, 2008 ===
 +
* This is the date on the survey report: [[Media:DT_A1191.pdf]].  The actual survey was done closer to Oct. 14th.
 +
<b>IMPORTANT NOTES:</b>
 +
o The electron detector stack was moved 9cm closer to the target on Oct. 24th.  That change is <i>not</i> reflected in this survey.

Revision as of 10:47, 29 October 2008

BigBite dipole magnet

Electron Package

Electron package layout drawings

o  Detector package with dimensions, updated by Al Gavalya 10/27/2008. side view and top view

BigBite spectrometer layout drawings, with the electron detector package

o  Magnet and detector relative to target center, with dimensions, updated by Susan Esp  10/27/2008. side view pdf file 

Gas Cherenkov Detector

Scintillators

Shower/Preshower Detectors

Position Survey

Sept 18, 2008

Notice: Terminology used in this section follows conventions of Hall A Tech Notes JLAB-TN-02-012:

BigBite Chamber center position are surveyed with laser markers and a hand held laser meter. Error could be between 1mm to 5mm.

  • Center of 1st Chamber Outer Aluminum Plate in BigBite Target Coordinate System:
    • X= -0.072m
    • Y= unknown
    • Z=2.862m
  • Bigbite Magnetic in BigBite Target Coordinate System:
    • Front Shielding Plate @Z=1.590m
    • At Beam Height, Edge of Bigbite Coil at Detector Side @Z=2.46m


Oct. 28, 2008

  • This is the date on the survey report: Media:DT_A1191.pdf. The actual survey was done closer to Oct. 14th.

IMPORTANT NOTES:

o The electron detector stack was moved 9cm closer to the target on Oct. 24th.  That change is not reflected in this survey.