Difference between revisions of "BigBite Spectrometer"

From Hall A Wiki
Jump to: navigation, search
(Sept 18, 2008)
(BigBite spectrometer layout drawings, with the electron detector package)
Line 11: Line 11:
 
===BigBite spectrometer layout drawings, with the electron detector package===
 
===BigBite spectrometer layout drawings, with the electron detector package===
  
  o  Magnet and detector relative to target center, with dimensions, updated by Susan Esp  10/27/2008. [http://hallaweb.jlab.org/experiment/transversity/wikifile/Big_Bite_Spectrometer_Sect.pdf side view pdf file]  
+
  o  Magnet and detector relative to target center, with dimensions the ideal position, but not the reality !!! updated by Susan Esp  10/27/2008. [http://hallaweb.jlab.org/experiment/transversity/wikifile/Big_Bite_Spectrometer_Sect.pdf side view pdf file]  
  
 
* [[Drift Chambers]]
 
* [[Drift Chambers]]

Revision as of 18:14, 4 November 2008

BigBite dipole magnet

Electron Package

Electron package layout drawings

o  Detector package with dimensions, updated by Al Gavalya 10/27/2008. side view and top view

BigBite spectrometer layout drawings, with the electron detector package

o  Magnet and detector relative to target center, with dimensions the ideal position, but not the reality !!! updated by Susan Esp  10/27/2008. side view pdf file 

Gas Cherenkov Detector

Scintillators

Shower/Preshower Detectors

Position Survey

Sept 18, 2008

Notice: Terminology used in this section follows conventions of Hall A Tech Notes JLAB-TN-02-012:

BigBite Chamber center position are surveyed with laser markers and a hand held laser meter. Error could be between 1mm to 5mm.

  • Center of 1st Chamber Outer Aluminum Plate in BigBite Target Coordinate System:
    • X= -0.072m
    • Y= unknown
    • Z= 2.862m
  • Bigbite Magnetic in BigBite Target Coordinate System:
    • Front Shielding Plate @Z=1.154m
    • At Beam Height, Edge of Bigbite Coil at Detector Side @Z=2.46m

Oct. 28, 2008

  • This is the date on the survey report: Media:DT_A1191.pdf. The actual survey was done closer to Oct. 14th.

IMPORTANT NOTES:

o The electron detector stack was moved 9cm closer to the target on Oct. 24th.  That change is not reflected in this survey.