Difference between revisions of "IOC reboot"
(→Feedback parameters) |
|||
(5 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | IOC is iochacp - might need to reboot from the hall. | + | IOC is iochacp - might need to reboot from the hall. |
− | + | No longer connected to terminal server. Can only reboot using remote power strip. | |
− | + | hareboot4. Outlet 4 | |
Before rebooting, make sure the cavity locking/unlocking script is OFF. | Before rebooting, make sure the cavity locking/unlocking script is OFF. | ||
− | After rebooting, | + | Note that the ioc communicates with the fiber amp via a portserver (hatsv43). If everything else is updating, but not the fiber amp, it might be that the portserver needs rebooting. |
+ | |||
+ | After rebooting, QWP1 will probably be set incorrectly (the HWP and QWP2 should not move). Check the position readback, and put it back where it was. The feedback parameters will also get reset - make sure to adjust them. | ||
== Power meter calibrations == | == Power meter calibrations == | ||
− | This needs updating | + | This needs updating - commands below are absolute. |
# caput COMPTON_PW3R_S2_ca.B 7.9264 | # caput COMPTON_PW3R_S2_ca.B 7.9264 | ||
# caput COMPTON_PW2R_S2_ca.B 11.833 | # caput COMPTON_PW2R_S2_ca.B 11.833 | ||
Line 16: | Line 18: | ||
==Feedback parameters== | ==Feedback parameters== | ||
− | |||
− | # caput COMPTON_SERVO_GAINao | + | # caput COMPTON_SERVO_GAINao 135 |
− | # caput COMPTON_SERVO_SEUILao | + | # caput COMPTON_SERVO_SEUILao 1 |
==Slow Ramp Parameters== | ==Slow Ramp Parameters== | ||
Line 26: | Line 27: | ||
==Initialize the QWP and HWP== | ==Initialize the QWP and HWP== | ||
+ | Needs updating | ||
+ | |||
# Send wave plates to 0 degrees | # Send wave plates to 0 degrees | ||
# caput COMPTON_ORX_bo 1 | # caput COMPTON_ORX_bo 1 | ||
Line 38: | Line 41: | ||
==Set exit line QWP== | ==Set exit line QWP== | ||
+ | This needs updating. | ||
# Send QWP HOME | # Send QWP HOME | ||
# caput COMPTON_ORY_bo 1 | # caput COMPTON_ORY_bo 1 |
Latest revision as of 12:14, 25 July 2019
IOC is iochacp - might need to reboot from the hall.
No longer connected to terminal server. Can only reboot using remote power strip.
hareboot4. Outlet 4
Before rebooting, make sure the cavity locking/unlocking script is OFF.
Note that the ioc communicates with the fiber amp via a portserver (hatsv43). If everything else is updating, but not the fiber amp, it might be that the portserver needs rebooting.
After rebooting, QWP1 will probably be set incorrectly (the HWP and QWP2 should not move). Check the position readback, and put it back where it was. The feedback parameters will also get reset - make sure to adjust them.
Contents
Power meter calibrations
This needs updating - commands below are absolute.
- caput COMPTON_PW3R_S2_ca.B 7.9264
- caput COMPTON_PW2R_S2_ca.B 11.833
- caput COMPTON_LASERPCAV_ca.A 13630
Feedback parameters
- caput COMPTON_SERVO_GAINao 135
- caput COMPTON_SERVO_SEUILao 1
Slow Ramp Parameters
- caput COMPTON_SLOWRAMP_AMPLITUDE 0.02
- caput COMPTON_SLOWRAMP_PERIOD 180.0
Initialize the QWP and HWP
Needs updating
- Send wave plates to 0 degrees
- caput COMPTON_ORX_bo 1
- caput COMPTON_ORZ_bo 1
- wait 2 minutes
- caput COMPTON_PVAL_X_ao 11909
- caput COMPTON_PVAL_Z_ao 5725
- caput COMPTON_LMOVX_bo 1
- caput COMPTON_LMOVZ_bo 1
This should set the QWP angle to 47.63 degrees and the HWP to 22.9 degrees
Set exit line QWP
This needs updating.
- Send QWP HOME
- caput COMPTON_ORY_bo 1
- Wait 2 minutes
- Set angle to approximately equalize power in integrating spheres
- caput COMPTON_PVAL_Y_ao 11162
- caput COMPTON_RMOVY_bo 1