Difference between revisions of "SBS DAQ meetings"

From Hall A Wiki
Jump to: navigation, search
(October 4th 2019)
Line 3: Line 3:
  
 
*Bigbite DAQ status ( Eric )
 
*Bigbite DAQ status ( Eric )
 +
-slide here
 +
-Eric should look at existing PODD classes for shower to decode Fastbus
 +
-Shower trigger  : less than 200 ns
 +
-test trigger lines : 190 ns
  
  
*HCAL DAQ status
+
*HCAL DAQ status ( Scott )
 +
-2 crates : 1 VXS crates with FADC and 1 VME64X with F1 and FADC
 +
-see cosmics in both crates in FADC , missing in TDC ( need to check new timing with 2 crates )
 +
-resolution lock issue with F1, might be overheating
 +
-add blanks to improve cooling
 +
-reduce resolution of F1 to see if problem goes away
 +
- latency from TI ( OT2 is prompt output less delay down to 200 ns)
 +
 
 +
*UVA GEM status (Byran / Kondo )
 +
- 3 VME crates in clean room with TI ( 2 VME and 1 VXS ) : 2 planes per crate , 1 TI and one fiber, need 1 TI with two transceiver
 +
-using CODA3
 +
-wiki with information on wiki :
 +
-computer ready soon
 +
-3rd (VXS) crate with SSP and MPDs
 +
 
 +
*SSP readout ( Ben )
 +
- 16 MPD for 1 SSP to be tested
 +
- all transceiver and fibers on site
 +
- test radiation hardness of transceivers and fibers
 +
 
 +
*BCM digital :
 +
- daughter board design done, need to make prototypes and test
 +
 
 +
 
 +
*Certification of electronics : need to check with Ed Folts ( Nilanga question )

Revision as of 11:41, 4 October 2019

October 4th 2019

  • Bigbite DAQ status ( Eric )

-slide here -Eric should look at existing PODD classes for shower to decode Fastbus -Shower trigger  : less than 200 ns -test trigger lines : 190 ns


  • HCAL DAQ status ( Scott )

-2 crates : 1 VXS crates with FADC and 1 VME64X with F1 and FADC -see cosmics in both crates in FADC , missing in TDC ( need to check new timing with 2 crates ) -resolution lock issue with F1, might be overheating -add blanks to improve cooling -reduce resolution of F1 to see if problem goes away - latency from TI ( OT2 is prompt output less delay down to 200 ns)

  • UVA GEM status (Byran / Kondo )

- 3 VME crates in clean room with TI ( 2 VME and 1 VXS ) : 2 planes per crate , 1 TI and one fiber, need 1 TI with two transceiver -using CODA3 -wiki with information on wiki : -computer ready soon -3rd (VXS) crate with SSP and MPDs

  • SSP readout ( Ben )

- 16 MPD for 1 SSP to be tested - all transceiver and fibers on site - test radiation hardness of transceivers and fibers

  • BCM digital :

- daughter board design done, need to make prototypes and test


  • Certification of electronics : need to check with Ed Folts ( Nilanga question )