Line 20: | Line 20: | ||
== Beamline, beam charge, beam polarization, Luminosity monitors == | == Beamline, beam charge, beam polarization, Luminosity monitors == | ||
# BPM A and B (x,) positions | # BPM A and B (x,) positions | ||
− | # Beam charge asymmetry is | + | #* Check the front room white borad for default value |
+ | # Beam charge asymmetry is small (less than 1000ppm)? (Check end-of-run, and check [[beam charge asymmetry stripchart]]) [[Image:Bcm asym stripchart.jpg|thumb|[[beam charge asymmetry stripchart]]]] | ||
# Lumi signals and replay OK ?, no saturation ?. | # Lumi signals and replay OK ?, no saturation ?. | ||
− | # Beam charge at end-of-run make sense ? | + | #* [http://compton.physics.wm.edu/~joe/upload/lumiCheck.html Shift Worker Checklist] |
+ | #* [http://compton.physics.wm.edu/~joe/upload/lumiExpert.html Expert HV Change Instructions] | ||
+ | # Beam charge at end-of-run make sense ? | ||
+ | #* all BCM charge reading should be consistent | ||
+ | #* Example of Good Run: | ||
+ | <pre> | ||
+ | APPROXIMATE BCM CHARGES (C) | ||
+ | BCM u1 [ 0]:0.03799 BCM u3 [ 0]:0.03798 BCM u10[ 0]:0.0336 | ||
+ | BCM u1 [++]:0.009217 BCM u3 [++]:0.009211 BCM u10[++]:0.008148 | ||
+ | BCM u1 [--]:0.009464 BCM u3 [--]:0.009462 BCM u10[--]:0.008371 | ||
+ | BCM u1 [+-]:0.009214 BCM u3 [+-]:0.009211 BCM u10[+-]:0.008148 | ||
+ | BCM u1 [-+]:0.009466 BCM u3 [-+]:0.009465 BCM u10[-+]:0.008373 | ||
+ | |||
+ | BCM d1 [ 0]:0.03786 BCM d3 [ 0]:0.03787 BCM d10[ 0]:0.03787 | ||
+ | BCM d1 [++]:0.009183 BCM d3 [++]:0.009198 BCM d10[++]:0.009188 | ||
+ | BCM d1 [--]:0.009428 BCM d3 [--]:0.009432 BCM d10[--]:0.009432 | ||
+ | BCM d1 [+-]:0.009182 BCM d3 [+-]:0.009185 BCM d10[+-]:0.009185 | ||
+ | BCM d1 [-+]:0.009431 BCM d3 [-+]:0.009434 BCM d10[-+]:0.009436 | ||
+ | </pre> | ||
== Run information == | == Run information == | ||
Line 32: | Line 51: | ||
# Confirm CODA not crashed, check DAQ-configuration: twoarm_RICH. | # Confirm CODA not crashed, check DAQ-configuration: twoarm_RICH. | ||
# Check Halog entries. | # Check Halog entries. | ||
− | # Check if spin-flip is ON. Check target polarization history. | + | # Check if spin-flip is ON. Check target polarization history. [[Image:3Ext Polarization.png|thumb|Example plot of a stable target]] |
+ | ## Go To [http://www.jlab.org/~jinhuang/TargetStatus/ Target Status History] | ||
+ | ## Check 1st or 3rd plot of Hall A Target Polarization | ||
+ | ##* Make sure the ''haPolHe3_Spin_State'' is changing every 20min (blue square wave) | ||
+ | ##* Check whether Target Polarization ''haPolHe3_Flip_NMR_Pol'' is stable (dark red square wave) | ||
# Check all HV on. BB chamber HV on before run starts. | # Check all HV on. BB chamber HV on before run starts. | ||
+ | #* [http://www.jlab.org/~adaq/halog/html/0811_archive/081129132504.html Example Start Run with All HV On] | ||
+ | #* Check Section | ||
+ | #** Left S2 HV Left/Right PMTs | ||
+ | #** Left S1/Cerenkov/A1 Cerenkov HV | ||
+ | #** Left Pion Rejector Layer 1/2 HV | ||
+ | #** Map BB_SC_R Measured Voltage/Current | ||
+ | #** Map BB_DC Measured Voltage/Current | ||
+ | #** Map BB_PS_R Measured Voltage/Current | ||
+ | #** Map BB_SC_L Measured Voltage/Current | ||
+ | #** Map BB_PS_L Measured Voltage/Current | ||
+ | #** Map BB_SH Measured Voltage/Current | ||
# Halog left arm VDC efficiency plots once a shift | # Halog left arm VDC efficiency plots once a shift | ||
+ | # Do [[Compton monitoring]] | ||
== [[Online_Replay#Expert_Info|Replay]] == | == [[Online_Replay#Expert_Info|Replay]] == | ||
− | [[Online_Replay#HowTo_Quick_Check_Root_File_Replayed_by_Shift_Worker|Run show_all(<run number>) script]] after shift worker finish a replay. It will pop up a set of plots for expert, which would take ~10min to check through. | + | [[Online_Replay#HowTo_Quick_Check_Root_File_Replayed_by_Shift_Worker|Run show_all(<run number>) script]] after shift worker finish a replay. It will pop up a set of plots for expert, which would take ~10min to check through. |
A list of minimum check items : (Item / {{pass|related online plots}}) | A list of minimum check items : (Item / {{pass|related online plots}}) | ||
Line 47: | Line 82: | ||
# Check scaler consistency / {{pass|online("scalar",run#)}} | # Check scaler consistency / {{pass|online("scalar",run#)}} | ||
# Spot++ / {{pass|equavlent plots (raster current, BPMs) are included in online("detectorL",run#)}} | # Spot++ / {{pass|equavlent plots (raster current, BPMs) are included in online("detectorL",run#)}} | ||
+ | |||
+ | ''Hint : You can try to do_all() the golden run to find out what a normal plots should look like'' | ||
== A list of known problems / possible bad runs == | == A list of known problems / possible bad runs == | ||
Line 52: | Line 89: | ||
# Left-arm VDC gas problem, low efficiency. | # Left-arm VDC gas problem, low efficiency. | ||
# Left-arm TDC shifts, symptom is current run and golden run shows significant difference in TDC times. | # Left-arm TDC shifts, symptom is current run and golden run shows significant difference in TDC times. | ||
+ | # Spin Flip is paused | ||
== Helpful Resources == | == Helpful Resources == |
Latest revision as of 17:51, 15 December 2008
Quick Links:
This is the check list for experts on transversity data checker shift.
Notice : Please add items of your specialty field, so every one will do the check
Contents
Beamline, beam charge, beam polarization, Luminosity monitors
- BPM A and B (x,) positions
- Check the front room white borad for default value
- Beam charge asymmetry is small (less than 1000ppm)? (Check end-of-run, and check beam charge asymmetry stripchart)
- Lumi signals and replay OK ?, no saturation ?.
- Beam charge at end-of-run make sense ?
- all BCM charge reading should be consistent
- Example of Good Run:
APPROXIMATE BCM CHARGES (C) BCM u1 [ 0]:0.03799 BCM u3 [ 0]:0.03798 BCM u10[ 0]:0.0336 BCM u1 [++]:0.009217 BCM u3 [++]:0.009211 BCM u10[++]:0.008148 BCM u1 [--]:0.009464 BCM u3 [--]:0.009462 BCM u10[--]:0.008371 BCM u1 [+-]:0.009214 BCM u3 [+-]:0.009211 BCM u10[+-]:0.008148 BCM u1 [-+]:0.009466 BCM u3 [-+]:0.009465 BCM u10[-+]:0.008373 BCM d1 [ 0]:0.03786 BCM d3 [ 0]:0.03787 BCM d10[ 0]:0.03787 BCM d1 [++]:0.009183 BCM d3 [++]:0.009198 BCM d10[++]:0.009188 BCM d1 [--]:0.009428 BCM d3 [--]:0.009432 BCM d10[--]:0.009432 BCM d1 [+-]:0.009182 BCM d3 [+-]:0.009185 BCM d10[+-]:0.009185 BCM d1 [-+]:0.009431 BCM d3 [-+]:0.009434 BCM d10[-+]:0.009436
Run information
- Check scaler rate screen, pre-scale factors agree with earlier runs. example of normal rate @ 12uA prodction
- Check online CODA rate and CODA dead time. (Run scaler script, verify deadtime)
- Check start-of-run input. Target type, beam half wave plate, etc.
- Happex run start ahead of transversity run ? (Happex run ends every four hours or so ?)
- Look at shift worker's run-sheet records.
- Confirm CODA not crashed, check DAQ-configuration: twoarm_RICH.
- Check Halog entries.
- Check if spin-flip is ON. Check target polarization history.
- Go To Target Status History
- Check 1st or 3rd plot of Hall A Target Polarization
- Make sure the haPolHe3_Spin_State is changing every 20min (blue square wave)
- Check whether Target Polarization haPolHe3_Flip_NMR_Pol is stable (dark red square wave)
- Check all HV on. BB chamber HV on before run starts.
- Example Start Run with All HV On
- Check Section
- Left S2 HV Left/Right PMTs
- Left S1/Cerenkov/A1 Cerenkov HV
- Left Pion Rejector Layer 1/2 HV
- Map BB_SC_R Measured Voltage/Current
- Map BB_DC Measured Voltage/Current
- Map BB_PS_R Measured Voltage/Current
- Map BB_SC_L Measured Voltage/Current
- Map BB_PS_L Measured Voltage/Current
- Map BB_SH Measured Voltage/Current
- Halog left arm VDC efficiency plots once a shift
- Do Compton monitoring
Replay
Run show_all(<run number>) script after shift worker finish a replay. It will pop up a set of plots for expert, which would take ~10min to check through.
A list of minimum check items : (Item / related online plots)
- Check left-HRS VDC efficiency / online("detectorL",run#)
- Check left-HRS VDC time / online("detectorL",run#)
- Check BB chamber wire map / online("detectorBB",run#)
- Check BB shower vs preshower ADC plot, threshold not changed / online("physics",run#)
- Check scaler consistency / online("scalar",run#)
- Spot++ / equavlent plots (raster current, BPMs) are included in online("detectorL",run#)
Hint : You can try to do_all() the golden run to find out what a normal plots should look like
A list of known problems / possible bad runs
- BB chamber HV not on all the time.
- Left-arm VDC gas problem, low efficiency.
- Left-arm TDC shifts, symptom is current run and golden run shows significant difference in TDC times.
- Spin Flip is paused