Difference between revisions of "Cosmics in TEDf"

From Hall A Wiki
Jump to: navigation, search
(Current Set Up for Running with Cosmics in TEDf (Feb 2021))
Line 3: Line 3:
 
* 2 CAEN v1190 TDCs (recording time information from all 180 channels)
 
* 2 CAEN v1190 TDCs (recording time information from all 180 channels)
 
* 2 v792 QDCs (recording charge information from subsets of 64 channels at a time)
 
* 2 v792 QDCs (recording charge information from subsets of 64 channels at a time)
* 12 NINO cads operating with AGILENT PSU and operating with internal threshold set by potentiometer on cards
+
* 12 NINO cards operating with AGILENT PSU and operating with internal threshold set by potentiometer on cards
 
* HV supplied by CAEN SY1527N main frame equipped with 1x A1531 primary PSU (have 3 spare) and 4x A1932A 48 channel HV distributer modules (have 4 spare)
 
* HV supplied by CAEN SY1527N main frame equipped with 1x A1531 primary PSU (have 3 spare) and 4x A1932A 48 channel HV distributer modules (have 4 spare)
  

Revision as of 07:45, 9 February 2021

Current Set Up for Running with Cosmics in TEDf (Feb 2021)

  • 89 bars
  • 2 CAEN v1190 TDCs (recording time information from all 180 channels)
  • 2 v792 QDCs (recording charge information from subsets of 64 channels at a time)
  • 12 NINO cards operating with AGILENT PSU and operating with internal threshold set by potentiometer on cards
  • HV supplied by CAEN SY1527N main frame equipped with 1x A1531 primary PSU (have 3 spare) and 4x A1932A 48 channel HV distributer modules (have 4 spare)

CODA 3 and VME Readout Set Up Details

Details on ROC and coda3 setup etc to be added here:

  • Check ROL etc, crate slots etc

Running the DAQ and Analysis

  • account is bbhodo on tedbbdaq machine (contact local users directly for password)
  • To run coda:
  • To run analysis scripts: