Difference between revisions of "Thursday, November 17, 4:00pm ETD"
From Hall A Wiki
(→Agenda) |
(→Agenda) |
||
(2 intermediate revisions by 2 users not shown) | |||
Line 2: | Line 2: | ||
Presentations:<br><br> | Presentations:<br><br> | ||
* Updates to mollersim geometry (Juliette) | * Updates to mollersim geometry (Juliette) | ||
− | ** Added the hybrid coil | + | ** Added the hybrid coil (see [http://ace.phys.virginia.edu/MollerSpectrometer/209 elog 209]) |
− | ** Need to investigate effect of "necessary gaps" | + | ** Need to investigate effect of "necessary gaps" |
− | ** Need to properly code the collimators in the hybrid region | + | ** Need to properly code the collimators in the hybrid region (see [http://ace.phys.virginia.edu/MollerSpectrometer/205 elog 205]) |
<br> | <br> | ||
− | * Investigations of generators | + | * Investigations of generators (see Seamus' log entry [http://ace.phys.virginia.edu/MollerSpectrometer/210 elog 210]) |
** Add detectors right after target and right after "acceptance" collimator | ** Add detectors right after target and right after "acceptance" collimator | ||
** triple-check the current generator and compare result without energy loss to theory | ** triple-check the current generator and compare result without energy loss to theory | ||
Line 12: | Line 12: | ||
** use GEANT4 to get the pre-vertex energy loss (track backwards) | ** use GEANT4 to get the pre-vertex energy loss (track backwards) | ||
** add MS code and compare to the GEANT4 generated energy loss | ** add MS code and compare to the GEANT4 generated energy loss | ||
+ | <br> | ||
* Investigation of the physics lists | * Investigation of the physics lists | ||
** can use the "standard" physics lists - at least to compare | ** can use the "standard" physics lists - at least to compare | ||
** haven't truly double-checked, but have fixed issues with changing GEANT versions | ** haven't truly double-checked, but have fixed issues with changing GEANT versions | ||
<br> | <br> | ||
− | * | + | * Field configuration comparison update (Sereres) |
+ | ** fieldmap comparison (see [http://ace.phys.virginia.edu/MollerSpectrometer/211 elog 211]) | ||
== Minutes == | == Minutes == |
Latest revision as of 14:47, 17 November 2011
Agenda
Presentations:
- Updates to mollersim geometry (Juliette)
- Investigations of generators (see Seamus' log entry elog 210)
- Add detectors right after target and right after "acceptance" collimator
- triple-check the current generator and compare result without energy loss to theory
- compare to "GEANT4" generator results (let it run a long time)
- use GEANT4 to get the pre-vertex energy loss (track backwards)
- add MS code and compare to the GEANT4 generated energy loss
- Investigation of the physics lists
- can use the "standard" physics lists - at least to compare
- haven't truly double-checked, but have fixed issues with changing GEANT versions
- Field configuration comparison update (Sereres)
- fieldmap comparison (see elog 211)
Minutes
Return to Teleconferences
Return to MOLLER at 11 GeV E09-005