Difference between revisions of "He3 Target Test Items"

From Hall A Wiki
Jump to: navigation, search
(New page: = Cell Characterization =)
 
m (Target Holding Field)
 
(17 intermediate revisions by the same user not shown)
Line 1: Line 1:
= Cell Characterization =
+
== Target Holding Field ==
 +
* Field survey: field strengh, gradient
 +
* Field rotation glitch check
 +
 
 +
== Cell Characterization ==
 +
 
 +
=== Density ===
 +
* Filling density
 +
* Broadening of Alkali absorption
 +
* N2 density: filling density, pressure curve
 +
 
 +
=== Wall Thickness ===
 +
* Laser interference measurement: wall and window
 +
 
 +
=== Cell Volume/Geometry ===
 +
* Caliper method
 +
* Archimedes' method
 +
 
 +
== Optical Pumping System ==
 +
 
 +
=== Laser Optics ===
 +
* Laser power measurement
 +
* Laser spectrum measurement/Absorption adjustment
 +
* Calibrations of optics orientations, e.g. λ/4 plates
 +
* Laser polarization measurement
 +
* Optics alignment [http://userweb.jlab.org/~yqiang/files/target/alignment.pdf]
 +
* Power consumption at laser connectors (if there is any)
 +
 
 +
=== Oven ===
 +
* RTD calibration
 +
* Condition optimization: oven temperature as a function of gas flow and heater power
 +
 
 +
== Polarimetry ==
 +
 
 +
=== NMR ===
 +
* Q-curve measurement of all pickup coils to prevent resonance
 +
* Minimize pickup coil background with maximum RF power
 +
* Linearity check of amplifiers: preamplifier, lock-in amplifier
 +
* Flux calibration: pickup coil survey and flux calculation
 +
* He<sup>3</sup> NMRs: frequency and field sweeps (including NMRs during EPR calibration)
 +
* AFP loss measurement
 +
* Internal temperature measurement in pumping chamber using NMR
 +
* NMR cross calibration: frequency vs. field, different locations
 +
* Water NMR calibration: field sweep (frequency sweep as well if possible)
 +
 
 +
=== EPR ===
 +
* Characterization of feedback system: proportional and integration gains
 +
* D2 light detection optimization [http://userweb.jlab.org/~yqiang/files/target/EPR_D2/D2_signal.pdf]
 +
* EPR calibration: absolute polarization measurement
 +
* Cross check with water calibrated NMRs
 +
* D1 light EPR measurement (if using narrow-band laser)
 +
 
 +
== MISC Studies ==
 +
* Spin up time
 +
* Relaxation time: room temperature, high temperature
 +
* Optimization of pumping condition: laser power, oven temperature
 +
* Polarization gradient across cell
 +
 
 +
== Reference ==
 +
* [http://userweb.jlab.org/~yqiang/files/talks/20090129_Target_Analysis.pptx Target analysis procedure for Transversity]
 +
* [http://userweb.jlab.org/~yqiang/files/target/Long/Q-wave.pdf Solutions for non-phase-consvering mirrors using Q-wave plates]
 +
* [http://userweb.jlab.org/~yqiang/files/target/EPR_D2/EPR_D2_83.pdf Design of a D2 light collection system]

Latest revision as of 13:03, 9 January 2012

Target Holding Field

  • Field survey: field strengh, gradient
  • Field rotation glitch check

Cell Characterization

Density

  • Filling density
  • Broadening of Alkali absorption
  • N2 density: filling density, pressure curve

Wall Thickness

  • Laser interference measurement: wall and window

Cell Volume/Geometry

  • Caliper method
  • Archimedes' method

Optical Pumping System

Laser Optics

  • Laser power measurement
  • Laser spectrum measurement/Absorption adjustment
  • Calibrations of optics orientations, e.g. λ/4 plates
  • Laser polarization measurement
  • Optics alignment [1]
  • Power consumption at laser connectors (if there is any)

Oven

  • RTD calibration
  • Condition optimization: oven temperature as a function of gas flow and heater power

Polarimetry

NMR

  • Q-curve measurement of all pickup coils to prevent resonance
  • Minimize pickup coil background with maximum RF power
  • Linearity check of amplifiers: preamplifier, lock-in amplifier
  • Flux calibration: pickup coil survey and flux calculation
  • He3 NMRs: frequency and field sweeps (including NMRs during EPR calibration)
  • AFP loss measurement
  • Internal temperature measurement in pumping chamber using NMR
  • NMR cross calibration: frequency vs. field, different locations
  • Water NMR calibration: field sweep (frequency sweep as well if possible)

EPR

  • Characterization of feedback system: proportional and integration gains
  • D2 light detection optimization [2]
  • EPR calibration: absolute polarization measurement
  • Cross check with water calibrated NMRs
  • D1 light EPR measurement (if using narrow-band laser)

MISC Studies

  • Spin up time
  • Relaxation time: room temperature, high temperature
  • Optimization of pumping condition: laser power, oven temperature
  • Polarization gradient across cell

Reference