There is no “regulator” on the septum magnets. You must set each one manually.
+
SEPTA
DO NOT USE "Septum Ramp Controls".
+
*There is no regulator on the septum magnets. You must set each one manually to match the spectrometer dipole setting.
Use Septum Right Controls for the right side
+
*Type "<B>~adaq/bin/GetSeptaCurrent <P0></B>" on any adaq machine to calculate the necessary septa current.
Use Septum Left Controls for the left side 
+
*Use <I>Septum Right Controls</I> and <I>Septum Left Controls</I> to control the septa.  DO NOT USE <I>Septum Ramp Controls</I>.  
Use "~adaq/bin/GetSeptaCurrent <P0>" to calculate the current for P0 in GeV.
+
  
 +
<br>
  
The correct “tune” for the spectrometers is “g2p/Gep_1” which you’ll see on the regulator
+
SPECTROMETERS
controls page (The button to the right of GeV/c after the P0 set box). This determines the
+
*The correct tune for the spectrometers is <I>g2p/Gep_1</I> which you’ll see on the regulator controls page (The button to the right of GeV/c after the P0 set box). This determines the quadrupole and dipole settings for the spectrometer proper.
quadrupole and dipole settings for the spectrometer proper.
+
*Make sure the regulator is ON during normal running.
Make sure the regulator is ON during normal running.
+
 
 +
<br>
 +
 
 +
ALARM
 +
*HowTo Set the [http://hallaweb.jlab.org/halog/log/html/1204_archive/120422125129.html Septa Alarm]

Latest revision as of 13:30, 22 April 2012

SEPTA

  • There is no regulator on the septum magnets. You must set each one manually to match the spectrometer dipole setting.
  • Type "~adaq/bin/GetSeptaCurrent <P0>" on any adaq machine to calculate the necessary septa current.
  • Use Septum Right Controls and Septum Left Controls to control the septa. DO NOT USE Septum Ramp Controls.


SPECTROMETERS

  • The correct tune for the spectrometers is g2p/Gep_1 which you’ll see on the regulator controls page (The button to the right of GeV/c after the P0 set box). This determines the quadrupole and dipole settings for the spectrometer proper.
  • Make sure the regulator is ON during normal running.


ALARM