− | How to | + | How to update the pedstal value for left and right arm: |
+ | (1) | ||
+ | First copy "ped1.dat,ped2.dat,ped3.dat,ped4.dat" and " ped_right.pl","ped_left.pl" to the same directory. | ||
− | + | "ped_left.pl" can be found in "/adaqfs/home/adaq/e05110/onlana/xinhu/analysis/CSRdetector/Calibration/pedstal/leftarm". | |
− | " | + | "ped_right.pl" can be found in "/adaqfs/home/adaq/e05110/onlana/xinhu/analysis/CSRdetector/Calibration/pedstal/rightarm". |
− | + | ||
− | "ped1.dat,ped2.dat" | + | For right arm: "ped1.dat,ped2.dat" can be obtained from "/net/fs.home/adev/ped" |
− | "ped3.dat,ped4.dat" | + | |
+ | For left arm: "ped3.dat,ped4.dat" can be obtained from "/net/fs.home/a-onl/ped/" | ||
And then exec: | And then exec: | ||
− | >ped_left.pl; | + | >ped_left.pl; #get pedsatal velue for correspond detector of left arm |
− | >ped_right.pl; | + | >ped_right.pl; #get pedsatal velue for correspond detector of right arm |
+ | |||
+ | |||
+ | (2)another way,if you get a cosmic run,you can use the following macro to get the pedstals for the detector of left arm: | ||
+ | |||
+ | For NaI : getped_NaI.C | ||
+ | |||
+ | For Prl1: getprl1.C | ||
+ | |||
+ | For Prl2: getprl2.C | ||
+ | |||
+ | the directory is : | ||
+ | /adaqfs/home/adaq/e05110/onlana/xinhu/analysis/CSRdetector/Calibration/pedstal |
Latest revision as of 22:25, 6 November 2007
How to update the pedstal value for left and right arm:
(1) First copy "ped1.dat,ped2.dat,ped3.dat,ped4.dat" and " ped_right.pl","ped_left.pl" to the same directory.
"ped_left.pl" can be found in "/adaqfs/home/adaq/e05110/onlana/xinhu/analysis/CSRdetector/Calibration/pedstal/leftarm".
"ped_right.pl" can be found in "/adaqfs/home/adaq/e05110/onlana/xinhu/analysis/CSRdetector/Calibration/pedstal/rightarm".
For right arm: "ped1.dat,ped2.dat" can be obtained from "/net/fs.home/adev/ped"
For left arm: "ped3.dat,ped4.dat" can be obtained from "/net/fs.home/a-onl/ped/"
And then exec:
>ped_left.pl; #get pedsatal velue for correspond detector of left arm >ped_right.pl; #get pedsatal velue for correspond detector of right arm
(2)another way,if you get a cosmic run,you can use the following macro to get the pedstals for the detector of left arm:
For NaI : getped_NaI.C
For Prl1: getprl1.C
For Prl2: getprl2.C
the directory is : /adaqfs/home/adaq/e05110/onlana/xinhu/analysis/CSRdetector/Calibration/pedstal