== Minutes ==
 
== Minutes ==
Attendance:
+
Attendance: Wouter, Seamus, Nilanga, David A., Rupesh, Mark P.
 +
 
 +
*Dave A.
 +
** 4 GEMs, provide wiggle room for inefficiencies and failures
 +
 
 +
*Nilanga:
 +
** ~95% efficiency - what we have measured so far
 +
** GEMs need to be out of vacuum
 +
** Need not worry about vacuum
 +
** With GEMs we can have resolution of about 100 um or so.
 +
** Can we improve th-th_rec by using 100 um instead of 500um
 +
 
 +
*David A./Seamus:
 +
** We need to be using r/dr as cuts, not th
 +
 
 +
*Mark P.
 +
** The detector scans needed for Moller events, not ep
 +
 
 +
*David A.
 +
** Interested in Moller asymmetries
 +
** Collimator motions are important
 +
** Maybe eps will be sensitive to small angles
 +
 
 +
*Mark P.
 +
** Tolerances of positioning collimator hole
 +
** Does this change the distribution of millers, eps at the detector?
 +
 
 +
* Things to do:
 +
** Inner/out collimator motion
 +
** p6. plots with GEM resolution much worse
 +
*** If 100um GEM res reduces the diff widths, then good,
 +
else these widths are not determined by the tracking system.
 +
 
 +
*Seamus
 +
** 5m between the first and last GEMs -> Move the first/second GEMs closer to downstream GEMs
 +
 
 +
*David A.
 +
** Main purpose of good resolution is to verify that we have valid tracks
 +
** The distributions that we have are not going to change very much with resolution, I suspect
 +
 
 +
* Meet in a week, same time.

Latest revision as of 11:46, 9 July 2013

Logistic information

   Phone number:  1-866-740-1260
   Access code:   1978431#

Agenda

http://ace.phys.virginia.edu/MollerSpectrometer/259

Minutes

Attendance: Wouter, Seamus, Nilanga, David A., Rupesh, Mark P.

  • Dave A.
    • 4 GEMs, provide wiggle room for inefficiencies and failures
  • Nilanga:
    • ~95% efficiency - what we have measured so far
    • GEMs need to be out of vacuum
    • Need not worry about vacuum
    • With GEMs we can have resolution of about 100 um or so.
    • Can we improve th-th_rec by using 100 um instead of 500um
  • David A./Seamus:
    • We need to be using r/dr as cuts, not th
  • Mark P.
    • The detector scans needed for Moller events, not ep
  • David A.
    • Interested in Moller asymmetries
    • Collimator motions are important
    • Maybe eps will be sensitive to small angles
  • Mark P.
    • Tolerances of positioning collimator hole
    • Does this change the distribution of millers, eps at the detector?
  • Things to do:
    • Inner/out collimator motion
    • p6. plots with GEM resolution much worse
      • If 100um GEM res reduces the diff widths, then good,

else these widths are not determined by the tracking system.

  • Seamus
    • 5m between the first and last GEMs -> Move the first/second GEMs closer to downstream GEMs
  • David A.
    • Main purpose of good resolution is to verify that we have valid tracks
    • The distributions that we have are not going to change very much with resolution, I suspect
  • Meet in a week, same time.