Difference between revisions of "HRS checkout"

From Hall A Wiki
Jump to: navigation, search
 
(4 intermediate revisions by the same user not shown)
Line 1: Line 1:
This is the HRS checkout plan to be executed after beam is estabilshed on the target with BeO target with CW beam.
+
This is the HRS checkout plan to be executed after beam is estabilshed on the BeO target with CW beam.
  
'''HRS angle 15 degrees, momentum P0 = 2.0 GeV/c, Raster size = 3x3 mm, current = 5uA, target =  Carbon'''  
+
'''LHRS angle 15 degrees, RHRS angle= 33 degrees, momentum P0 = 2.0 GeV/c, Raster size = 3x3 mm, current = 5uA, target =  Carbon'''  
  
 
Take Left and Right HRS runs in the following order. Always keep deadtime to below 10 %  
 
Take Left and Right HRS runs in the following order. Always keep deadtime to below 10 %  
Line 22: Line 22:
  
  
 +
Single hole sive plate runs
 +
* Insert sigle hole thick sieve plate on Right (Left?) arm
 +
* Take data with trigger T1
  
Runs with single hole sive plate
+
 
*
+
More to come soon ...
*
+
 
    
 
    
  
  
[[12_GeV_March_2014_running]]
+
[[Run_plan]]

Latest revision as of 14:56, 16 March 2014

This is the HRS checkout plan to be executed after beam is estabilshed on the BeO target with CW beam.

LHRS angle 15 degrees, RHRS angle= 33 degrees, momentum P0 = 2.0 GeV/c, Raster size = 3x3 mm, current = 5uA, target = Carbon

Take Left and Right HRS runs in the following order. Always keep deadtime to below 10 %

(adjust prescale value based on scaler rates for that trigger)

  • 1M events with T1 trigger, prescale values: ps1=non-zero, ps2=0, ps3=0, ps4=0, ps5=0, ps6=0, ps7=0, ps8=0
  • 1M events with T2 trigger, prescale values: ps1=0, ps2=non-zero, ps3=0, ps4=0, ps5=0, ps6=0, ps7=0, ps8=0
  • 1M events with T3 trigger, prescale values: ps1=0, ps2=0, ps3=non-zero, ps4=0, ps5=0, ps6=0, ps7=0, ps8=0
  • 1M events with T4 trigger, prescale values: ps1=0, ps2=0, ps3=0, ps4=non-zero, ps5=0, ps6=0, ps7=0, ps8=0
  • 1M events with T5 trigger, prescale values: ps1=0, ps2=0, ps3=0, ps4=0, ps5=non-zero, ps6=0, ps7=0, ps8=0
  • 1M events with T6 trigger, prescale values: ps1=0, ps2=0, ps3=0, ps4=0, ps5=0, ps6=non-zero, ps7=0, ps8=0
  • Fill run sheets, and log xscaler display for all the runs


Current vs rate study (carbon target)

  • Take runs for Left and Right HRS using T1 trigger at 1uA, 2uA , 3uA, 4uA, 5 uA each. Put prescale 0 for all other triggers
  • Log xscaler display on LHRS and RHRS, fill run sheets


Single hole sive plate runs

  • Insert sigle hole thick sieve plate on Right (Left?) arm
  • Take data with trigger T1


More to come soon ...


Run_plan