**HCAL | **HCAL | ||
+ | ***power cycled Rpi for threshold, no EPICS | ||
+ | ***took cosmics last night | ||
+ | ***LED working | ||
+ | ***Latency changed for cosmics | ||
+ | ***working on timing jitter using hodoscope | ||
**BigBite Shower | **BigBite Shower | ||
+ | ***took series of cosmics runs for best settings for the kinematic | ||
**BigBite hodoscope | **BigBite hodoscope | ||
+ | ***data looks ok | ||
+ | ***HV issues | ||
**GRINCH | **GRINCH | ||
+ | ***VETROC firmware updated, fixed most of missing channels | ||
+ | ***few ADC channels with no signal - need to figure out - might need to swap FADC | ||
+ | ***2 channels missing in TDC with one known dead PMT | ||
**CDet | **CDet | ||
+ | ***turned module around, 2nd half getting set up | ||
**GEM Bigbite | **GEM Bigbite | ||
+ | ***everything looks ok | ||
+ | ***negative pulses still need to be figured out, took data without suppression | ||
**GEM INFN | **GEM INFN | ||
+ | ***MPD7 fixed with cable | ||
**GEM GEN RP | **GEM GEN RP | ||
+ | ***working on database to look at the data | ||
+ | **Beamline/Helicity | ||
+ | ***figured out issue when putting data in the tree | ||
− | * | + | |
+ | *Issues | ||
+ | **HCAL LED jitter : fixed | ||
+ | **GEM latency different for different places in detector | ||
+ | **GRINCH missing channels | ||
+ | **New MPD firmware | ||
+ | **Hodo EPICS HV : still need to test |
Latest revision as of 11:51, 21 January 2022
- Updates
- HCAL
- power cycled Rpi for threshold, no EPICS
- took cosmics last night
- LED working
- Latency changed for cosmics
- working on timing jitter using hodoscope
- BigBite Shower
- took series of cosmics runs for best settings for the kinematic
- BigBite hodoscope
- data looks ok
- HV issues
- GRINCH
- VETROC firmware updated, fixed most of missing channels
- few ADC channels with no signal - need to figure out - might need to swap FADC
- 2 channels missing in TDC with one known dead PMT
- CDet
- turned module around, 2nd half getting set up
- GEM Bigbite
- everything looks ok
- negative pulses still need to be figured out, took data without suppression
- GEM INFN
- MPD7 fixed with cable
- GEM GEN RP
- working on database to look at the data
- Beamline/Helicity
- figured out issue when putting data in the tree
- HCAL
- Issues
- HCAL LED jitter : fixed
- GEM latency different for different places in detector
- GRINCH missing channels
- New MPD firmware
- Hodo EPICS HV : still need to test