Difference between revisions of "Measurements"
From Hall A Wiki
(→Recent polarization measurements) |
(→Polarization Calibration Data) |
||
(5 intermediate revisions by 2 users not shown) | |||
Line 79: | Line 79: | ||
|- style="vertical-align:middle; background-color:#F9F9F9;" | |- style="vertical-align:middle; background-color:#F9F9F9;" | ||
|} | |} | ||
+ | |||
+ | First spin-up curve for Ukraine [https://logbooks.jlab.org/entry/4051692] | ||
+ | |||
+ | Important details on EPR for GEn-II [https://logbooks.jlab.org/entry/4052187] | ||
== Recent polarization measurements == | == Recent polarization measurements == | ||
+ | |||
+ | First NMR measurement for GEn-II [https://logbooks.jlab.org/entry/4051553] | ||
+ | |||
+ | First EPR measurement for GEn-II [https://logbooks.jlab.org/entry/4052023] | ||
+ | |||
After doing an NMR sweep, record the date, time, and polarization percentage. Link to a log entry in which you include a screenshot of the NMR Field Sweep Control Program. | After doing an NMR sweep, record the date, time, and polarization percentage. Link to a log entry in which you include a screenshot of the NMR Field Sweep Control Program. | ||
* date, time, polarization% : link to log entry | * date, time, polarization% : link to log entry | ||
Line 94: | Line 103: | ||
* 11/12/2022 04:22 44.6% : https://logbooks.jlab.org/entry/4081429 | * 11/12/2022 04:22 44.6% : https://logbooks.jlab.org/entry/4081429 | ||
* 11/12/2022 06:51 43.7% : https://logbooks.jlab.org/entry/4081499 | * 11/12/2022 06:51 43.7% : https://logbooks.jlab.org/entry/4081499 | ||
+ | * 11/13/2022 00:22 41.1% : https://logbooks.jlab.org/entry/4082136 | ||
+ | * 11/13/2022 02:28 40.9% : https://logbooks.jlab.org/entry/4082197 |
Latest revision as of 11:39, 22 December 2023
<< Back
Contents
Target Polarization Angle Conventions
Be VERY clear here about the convention (beam-right/left/up/downstream) vs 0, 90, 180, 270) for each run period. More notes and references to log entries are better.
Taking an NMR Measurement
- Make sure that the holding field settings are correct for whatever magnetic field settings you're working with.
- Note that if you have to change the holding field, you will then need to restart the NMR GUI once the holding field is in its new configuration.
- This can be done by pressing the red "stop" button in the top left hand corner and then the "run" button.
- Call MCC to mask the beam so that you can move the target to the "pickup coils" position.
- Make sure that the NMR GUI settings are correct. The high field should be 34G and all of the sensitivities should be 100. Make sure that the calibration constant is correct.
- In the white box on the bottom left hand side of the NMR GUI you can write a comment with convection and B field settings.
- Example of a comment would be "120W 245C 9V 5G/s 0.2Vrms bb/sbs on/on"
- Press the green "Start" button.
- A window will pop up that should contain the comment that you just wrote. If the comment isn't there do NOT press cancel!! Just rewrite your comment. You should also make sure the NMR constant is correct. And that it's recording for the correct target cell.
- Press the "Go ahead" button.
- Once the sweep is done, the number in the top right under "Polarization %" is the polarization that you should record in a log entry.
- Make a log entry titled "NMR Measurement 100%" (with the polarization percentage from the NMR sweep you just did) with a screenshot of the NMR controls GUI.
- Include a general status of the beam for the past couple of hours in your log entry.
- Move the target back to the original position.
- Record at the bottom of this page the date, time, and polarization of your measurement with a link to the halog entry.
Polarization Calibration Data
ADD LIST OF CALIBRATION RUNS HERE AND A TABLE OF RELEVANT CALIBRATION CONSTANTS TO USE FOR WHAT RUNS
Cell | Calibration Type |
SHMS Angle /degree |
SHMS Momentum /GeV |
Field Direction /degree |
Calibration Results | Status | Oven Temperature /°C |
Log# |
---|---|---|---|---|---|---|---|---|
Hunter | EPR-NMR | 11 | 7.5 | 90 | 5.24 %/mV | Done | 200 | 3839939 |
Hunter | EPR-NMR | 18 | 5.6 | 90 | undone | 205 | ||
Hunter | EPR-NMR | 11 | 7.5 | 270 | undone | 208 | ||
Hunter | AFP Loss | 14.5 | 6.4 | 90 | 1.25%/Sweep | Done | 200 | 3840618, 3840143, 3840618 |
First spin-up curve for Ukraine [1]
Important details on EPR for GEn-II [2]
Recent polarization measurements
First NMR measurement for GEn-II [3]
First EPR measurement for GEn-II [4]
After doing an NMR sweep, record the date, time, and polarization percentage. Link to a log entry in which you include a screenshot of the NMR Field Sweep Control Program.
- date, time, polarization% : link to log entry
- 11/11/2022 00:58 27.6% : https://logbooks.jlab.org/entry/4080494
- 11/11/2022 04:18 33.0% : https://logbooks.jlab.org/entry/4080593
- 11/11/2022 06:18 34.4% : https://logbooks.jlab.org/entry/4080670
- 11/11/2022 08:48 35.3% : https://logbooks.jlab.org/entry/4080756
- 11/11/2022 12:38 37.8% : https://logbooks.jlab.org/entry/4080941
- 11/11/2022 15:53 41.4% : https://logbooks.jlab.org/entry/4081069
- 11/11/2022 18:42 42.1% : https://logbooks.jlab.org/entry/4081135
- 11/11/2022 21:23 43.8% : https://logbooks.jlab.org/entry/4081188
- 11/12/2022 02:06 47.4% : https://logbooks.jlab.org/entry/4081337
- 11/12/2022 04:22 44.6% : https://logbooks.jlab.org/entry/4081429
- 11/12/2022 06:51 43.7% : https://logbooks.jlab.org/entry/4081499
- 11/13/2022 00:22 41.1% : https://logbooks.jlab.org/entry/4082136
- 11/13/2022 02:28 40.9% : https://logbooks.jlab.org/entry/4082197