Difference between revisions of "GEM HV Scan Runplan"

From Hall A Wiki
Jump to: navigation, search
(New page: = Draft HV Scan Runplan = *Setup **Ensure sieve is out for left arm **Move target to thin Carbon Target **Set Left HRS to standard non-PREX tune. Turn off p0 regulation to the quads, cyc...)
 
 
(2 intermediate revisions by the same user not shown)
Line 4: Line 4:
 
**Ensure sieve is out for left arm
 
**Ensure sieve is out for left arm
 
**Move target to thin Carbon Target
 
**Move target to thin Carbon Target
**Set Left HRS to standard non-PREX tune. Turn off p0 regulation to the quads, cycle Q2/Q3 if going to higher momentum  
+
**Set Left HRS magnets to fill the focal plane: Turn off p0 regulation to the quads, cycle Q2/Q3 if going to higher momentum and set to the following currents:
 
{| border = "1"
 
{| border = "1"
 
|-
 
|-
Line 22: Line 22:
 
**Prescale all triggers away except for T5
 
**Prescale all triggers away except for T5
 
**Ask for 200nA of beam
 
**Ask for 200nA of beam
**Adjust beam current such that T5 rate is ~50kHz
+
**Adjust beam current such that T5 rate is ~200kHz
 
**VDCs are ON
 
**VDCs are ON
 
**GEM HV On to low HV value (given below)
 
**GEM HV On to low HV value (given below)
Line 40: Line 40:
 
|-
 
|-
 
|}
 
|}
 +
 +
 +
  
 
*Backout
 
*Backout

Latest revision as of 13:12, 19 April 2010

Draft HV Scan Runplan

  • Setup
    • Ensure sieve is out for left arm
    • Move target to thin Carbon Target
    • Set Left HRS magnets to fill the focal plane: Turn off p0 regulation to the quads, cycle Q2/Q3 if going to higher momentum and set to the following currents:
I (A)
Q1 800
Q2 458
Q3 423
    • HV for upper scintillator is on
      • Left arm - LeCroy HV GUI, Card 2, Channel 10 (-1400V)
      • Right arm - telnet hatsv3 port 2005, Card 9, Channel 6 (-1400V)
    • Prescale all triggers away except for T5
    • Ask for 200nA of beam
    • Adjust beam current such that T5 rate is ~200kHz
    • VDCs are ON
    • GEM HV On to low HV value (given below)


  • Scan
    • Scan the HV settings for the chamber as given in the table below
    • Take 200k events at each step
Chamber Low HV High HV Step size
UVA 3400 3800 40
INFN 3600 4200 60



  • Backout
    • VDCs Off
    • Trigger Scintillator off
    • GEM HV Off
    • Set LHRS back to PREX tune B: cycle quads if going to higher current, turn p0 regulation for 3 quads back on