Difference between revisions of "Preparation"
From Hall A Wiki
Line 1: | Line 1: | ||
* <span style="color:#ff0000"> Cable/HRS motion:</span> add cable length and re-route the needed cables. Disconnect the others ? | * <span style="color:#ff0000"> Cable/HRS motion:</span> add cable length and re-route the needed cables. Disconnect the others ? | ||
− | * Left cerenkov overflow: move ADC from ROC 3 to ROC 4. Could we split the signal between the existing ADC in ROC 3 and the ADC in ROC 4 ? | + | * <span style="color:#ff0000"> Left cerenkov overflow:</span> move ADC from ROC 3 to ROC 4. Could we split the signal between the existing ADC in ROC 3 and the ADC in ROC 4 ? |
− | * Deadtime: | + | * <span style="color:#ff0000"> Deadtime:</span> |
- remove the sequencer reading of BB and only read the main trigger module. | - remove the sequencer reading of BB and only read the main trigger module. | ||
- or set hight threshold on unused channels. | - or set hight threshold on unused channels. | ||
− | * Right arm Shower block 76 missing signal: check that it is at the bottom of the acceptance if cannot be fixed. | + | * <span style="color:#ff0000"> Right arm Shower block 76 missing signal:</span> check that it is at the bottom of the acceptance if cannot be fixed. |
− | * Right arm S1: one channel is noisy. | + | * <span style="color:#ff0000"> Right arm S1:</span> one channel is noisy. |
− | * Right arm Cerenkov: | + | * <span style="color:#ff0000"> Right arm Cerenkov:</span> |
- multi-peak in the TDCs: gate width problem ? | - multi-peak in the TDCs: gate width problem ? | ||
- no obvious single photon electron peak in ADCs: increase HV. | - no obvious single photon electron peak in ADCs: increase HV. | ||
− | * Right Q3: run Q3 at momentum ?% lower for each momentum setting. | + | * <span style="color:#ff0000"> Right Q3:</span> run Q3 at momentum ?% lower for each momentum setting. |
Revision as of 21:18, 10 April 2011
- Cable/HRS motion: add cable length and re-route the needed cables. Disconnect the others ?
- Left cerenkov overflow: move ADC from ROC 3 to ROC 4. Could we split the signal between the existing ADC in ROC 3 and the ADC in ROC 4 ?
- Deadtime:
- remove the sequencer reading of BB and only read the main trigger module. - or set hight threshold on unused channels.
- Right arm Shower block 76 missing signal: check that it is at the bottom of the acceptance if cannot be fixed.
- Right arm S1: one channel is noisy.
- Right arm Cerenkov:
- multi-peak in the TDCs: gate width problem ? - no obvious single photon electron peak in ADCs: increase HV.
- Right Q3: run Q3 at momentum ?% lower for each momentum setting.