== Cell Characterization ==
 
== Cell Characterization ==
 +
 +
=== Density ===
 +
* Filling density
 +
* Broadening of Alkali absorption
 +
 +
=== Wall Thickness ===
 +
* Laser interference measurement: wall and window
 +
 +
== Optical Pumping System ==
 +
 +
=== Laser Optics ===
 +
* Laser power measurement
 +
* Laser spectrum measurement/Absorption adjustment
 +
* Calibrations of optics orientations, e.g. λ/4 plates
 +
* Laser polarization measurement
 +
* Optics alignment
 +
* Power consumption at laser connectors (if there is any)
 +
 +
=== Oven ===
 +
* RTD calibration
 +
* Condition optimization: oven temperature as a function of gas flow and heater power
 +
 +
== Calorimetry ==
 +
 +
=== NMR ===
 +
* System Q-curve measurement of all pickup coils to prevent resonance
 +
* He<sup>3</sup> NMRs: frequency and field sweeps (including NMRs during EPR calibration)
 +
* AFP loss measurement
 +
* Internal temperature measurement in pumping chamber using NMR
 +
* NMR cross calibration: frequency vs. field, different locations
 +
* Water NMR: field sweep (frequency sweep as well if possible)
 +
* Flux calibration: pickup coil survey and flux calculation
 +
 +
=== EPR ===
 +
* EPR calibration
 +
* Cross check with water calibrated NMRs
 +
 +
== MISC Studies ==
 +
* Spin up time
 +
* Relaxation time: room temperature, high temperature
 +
* Optimization of pumping condition: laser power, oven temperature
 +
* Polarization gradient

Revision as of 12:03, 9 January 2012

Cell Characterization

Density

  • Filling density
  • Broadening of Alkali absorption

Wall Thickness

  • Laser interference measurement: wall and window

Optical Pumping System

Laser Optics

  • Laser power measurement
  • Laser spectrum measurement/Absorption adjustment
  • Calibrations of optics orientations, e.g. λ/4 plates
  • Laser polarization measurement
  • Optics alignment
  • Power consumption at laser connectors (if there is any)

Oven

  • RTD calibration
  • Condition optimization: oven temperature as a function of gas flow and heater power

Calorimetry

NMR

  • System Q-curve measurement of all pickup coils to prevent resonance
  • He3 NMRs: frequency and field sweeps (including NMRs during EPR calibration)
  • AFP loss measurement
  • Internal temperature measurement in pumping chamber using NMR
  • NMR cross calibration: frequency vs. field, different locations
  • Water NMR: field sweep (frequency sweep as well if possible)
  • Flux calibration: pickup coil survey and flux calculation

EPR

  • EPR calibration
  • Cross check with water calibrated NMRs

MISC Studies

  • Spin up time
  • Relaxation time: room temperature, high temperature
  • Optimization of pumping condition: laser power, oven temperature
  • Polarization gradient