Difference between revisions of "Spectrometer"
From Hall A Wiki
(→Left arm) |
(→Left arm) |
||
Line 4: | Line 4: | ||
===Left arm=== | ===Left arm=== | ||
*Left arm S1 Left S1 PMT 0 no ADC signal ( looks unplugged ) | *Left arm S1 Left S1 PMT 0 no ADC signal ( looks unplugged ) | ||
+ | *Left S1 TDC 2,3,4 need additionnal delay | ||
+ | *S2 TDC ADC Ok | ||
+ | *Gas Cerenkov signal on all channels | ||
*Low VDC efficiency ( maybe just trigger need to prescale T4 will see next run) | *Low VDC efficiency ( maybe just trigger need to prescale T4 will see next run) | ||
*pion rejector all channels have signals | *pion rejector all channels have signals | ||
− | |||
===Right arm=== | ===Right arm=== |
Revision as of 22:24, 4 February 2007
Spectrometer status and to-do list
January 3rd cosmics run 6003 / 26003
Left arm
- Left arm S1 Left S1 PMT 0 no ADC signal ( looks unplugged )
- Left S1 TDC 2,3,4 need additionnal delay
- S2 TDC ADC Ok
- Gas Cerenkov signal on all channels
- Low VDC efficiency ( maybe just trigger need to prescale T4 will see next run)
- pion rejector all channels have signals