===Assumptions:===
 
===Assumptions:===
Line 11: Line 10:
 
*Beam Permit but no beam on target
 
*Beam Permit but no beam on target
 
===Prepare Fridge:===
 
===Prepare Fridge:===
 +
*Ensure Blower 1 interlock light is on
 
*Close Roughing valve
 
*Close Roughing valve
 
*Turn on Blower 1 and wait 2 minutes
 
*Turn on Blower 1 and wait 2 minutes
 +
*Ensure Blower 2 interlock light is on
 
*Turn on Blower 2 and wait 2 minutes
 
*Turn on Blower 2 and wait 2 minutes
*Close Bypass valve
+
*Ensure Blower 3 interlock light is on
 
*Turn on Blower 3
 
*Turn on Blower 3
 +
*Close pump Bypass valve
 
*Wait a little while
 
*Wait a little while
 
===Begin Polarization:===
 
===Begin Polarization:===

Revision as of 11:12, 31 March 2012

Assumptions:

  • NMR System is tuned
  • Magnet is at full field, persistent mode, leads are ramped down
  • Nose is over 50%, run valve in PID mode
  • Baseline taken and set
  • TE has been taken and new calibration constant feed into PDP
  • Target in correct position along with NHR Channel setting
  • Roughing and Bypass valve open with mechanical pumps on
  • Beam Permit but no beam on target

Prepare Fridge:

  • Ensure Blower 1 interlock light is on
  • Close Roughing valve
  • Turn on Blower 1 and wait 2 minutes
  • Ensure Blower 2 interlock light is on
  • Turn on Blower 2 and wait 2 minutes
  • Ensure Blower 3 interlock light is on
  • Turn on Blower 3
  • Close pump Bypass valve
  • Wait a little while

Begin Polarization:

  • Press "TRANSMIT" on the microwave control panel under Control Unit Status (WARNING: Do not touch the button to the right)
  • Press "Take Data" on PDP
  • Try to maximize polarization by moving the bellows position
  • Watch the frequency in the top left monitor
  • You can try to start out in the frequency range in the plot of frequency vs Dose since last annel
  • Generally you have to search for the "best" frequency When searching, make changes by 5MHz, 10MHz at the most
  • After making a change, wait about 3 NMR updates to see if it helped/hurt
  • Beam trips will change pol quickly and obscure the effect of your changes especially over 50nA
  • If the frequencies display does not work look also at the poltarcama/Jpeg/CamImgs.jpg using Camera Set 0, use F5 to update (This shows in Hall bellows position)
  • As radiation damage accumulates, frequency will move if polarizing positively, frequency will move down and if polarizing negatively, frequency will move up
  • Use the logbook − see what frequencies worked for other people
  • Log all of your best frequencies when you find them in the Target Operator Microwave Frequency Notebook
  • Tell shift leader you are ready for beam