SEPTA
 
SEPTA
*There is no “regulator” on the septum magnets. You must set each one manually to match the spectrometer dipole setting.
+
*There is no regulator on the septum magnets. You must set each one manually to match the spectrometer dipole setting.
*Use "Septum Right Controls" and "Septum Left Controls" (DO NOT USE "Septum Ramp Controls". )
+
*Use <I>Septum Right Controls</I> and <I>Septum Left Controls</I>.  DO NOT USE <I>Septum Ramp Controls</I>.  
*Use "~adaq/bin/GetSeptaCurrent <P0>" to calculate the current for P0 in GeV.'''
+
*Type "<B>~adaq/bin/GetSeptaCurrent <P0></B>" on any adaq machine to calculate the necessary septa current.
 
<br>
 
<br>
  

Revision as of 14:56, 13 April 2012

SEPTA

  • There is no regulator on the septum magnets. You must set each one manually to match the spectrometer dipole setting.
  • Use Septum Right Controls and Septum Left Controls. DO NOT USE Septum Ramp Controls.
  • Type "~adaq/bin/GetSeptaCurrent <P0>" on any adaq machine to calculate the necessary septa current.


SPECTROMETERS

  • The correct “tune” for the spectrometers is “g2p/Gep_1” which you’ll see on the regulator controls page (The button to the right of GeV/c after the P0 set box). This determines the quadrupole and dipole settings for the spectrometer proper.
  • Make sure the regulator is ON during normal running.