Difference between revisions of "Solid Detector Dimension"
From Hall A Wiki
(→Introduction) |
(→current) |
||
Line 7: | Line 7: | ||
coil center at z=0, positive Z axis is going downstream along beam, x and y axis is according to right hand rule. | coil center at z=0, positive Z axis is going downstream along beam, x and y axis is according to right hand rule. | ||
− | = current = | + | = current (some numbers are outdated as 2013/05, please check with Zhiwen) = |
== SoLID CLEO (based on CLEOv8 field map) == | == SoLID CLEO (based on CLEOv8 field map) == |
Revision as of 21:34, 3 June 2013
Contents
Introduction
The SoLID layouts with different configuration are shown here.
The standard setup plot can be download from http://hallaweb.jlab.org/12GeV/SoLID/download/sim/setup/
coil center at z=0, positive Z axis is going downstream along beam, x and y axis is according to right hand rule.
current (some numbers are outdated as 2013/05, please check with Zhiwen)
SoLID CLEO (based on CLEOv8 field map)
CLEOv8 field map is based on more realistic design with CLEO-II.
The magnet and yoke will fit both PVDIS and SIDIS/JPsi configuration.
The detector has various small change to fit into new design, please refer to the change at slide 7 and 8 of CLEOv8 update pptx pdf
SIDIS/JPsi | Z center (cm) | Z range (cm) | Z length (cm) | R range (cm) | R length (cm) | area (m2) | weight(metric t) | comment |
---|---|---|---|---|---|---|---|---|
target (SIDIS) | -350 | (-370,-330) | 40 | (0,1) | 1 | |||
target collimator upstream (SIDIS) | -355 | (-360,-350) | 10 | Rin(1.2,2.4),Rout(4.9,9.8) | made of W | |||
target collimator downstream (SIDIS) | -300 | (-305,-295) | 10 | Rin(5.5,6.8),Rout(21.9,26.8) | made of W | |||
GEM | Z(-175,-150,-119,-68,5,92) | 1 per plane | Rin(45,26,30,37,46,58), Rout(80,93,107.5,135,98,122) | (35,67,77.5,98,52,64) | ||||
largeangle Calorimeter | -40 | Z(-65,-15) | 50 | Rin(75, 88),Rout(140, 140) | (66,50) | 4.5 | 9 (25%lead + 75%scintillator) | |
absorber largeangle | 70 | Z(60,80) | 20 | Rin(107.5,112.8),Rout(140,140) | (32.5,27.2) | 2.3 | 9 (Tungsten) | |
absorber forwardangle | 140 | Z(100,180) | 80 | Rin(16,19),Rout(50,60) | (34,39) | 0.85 | 13 (Tungsten) | can be smaller |
lightgas Cherenkov | Z(97,194,209,301) | 204 | Rin(58,65,67,85), Rout(127,144,155,265) | (69,79,88,180) | ||||
heavygas Cherenkov | 351 | Z(306,396) | 90 | Rin(86,98),Rout(265,265) | (179,167) | |||
MRPC | 400 | 1 | (99,201) | 101 | ||||
forwardangle Calorimeter | 430 | (405,455) | 50 | (100,215) | 115 | 11.4 | 23 (25%lead + 75%scintillator) | may share supporting with PVDIS FAEC |
Space at back | (455,485) | 30 | partially for EC readout | |||||
Beamline upstream | Z(-675,-375) | 300 | Rin(1.22,1.22), Rout(1.25,1.25) | 0.03 | ||||
Beamline downstream | Z(-325,500) | 825 | Rin(1.7,28.9),Rout(1.8,29.0) | 0.1 |
PVDIS | Z center (cm) | Z range (cm) | Z length (cm) | R range (cm) | R length (cm) | area (m2) | weight (t) | comment |
---|---|---|---|---|---|---|---|---|
target | 10 | (-10, 30) | 40 | (0, 1) | 1 | |||
Baffle | Z(40,68,96,124,152,180) | 9 per plate | Rin(3.9,15.3,26.6,37.9,49.2,60.4) Rout(34.7,54.3,73.8,93.3,112.8,132.0) | (30.8,39,47.2,93,55.4,63.6,71.6) | 15 | Eugene's baffle for BaBar | ||
GEM | Z (157.5,185.5,306,315) | 1 per plate | Rin(56,67,113,117),Rout(108,129,215,222) | (52,62,102,105) | ||||
lightgas Cherenkov | Z(194,209,301) | 107 | Rin(65,67,85),Rout(144,155,265) | (79,88,180) | ||||
forwardangle Calorimeter | 345 | (320,370) | 50 | (118,261) | 143 | 17 | 34 (25%lead + 75%scintillator) | may share supporting with SIDIS FAEC |
Space at back | 370 - 485 | 115 | partially for EC readout | |||||
Beamline upstream | Z(-675,-15) | 650 | Rin(1.22,1.22), Rout(1.25,1.25) | 0.03 | ||||
Beamline downstream | Z(35,500) | 465 | Rin(1.4,28.9),Rout(1.5,29.0) | 0.1 |
previous
SoLID CLEO (based on CLEOv5 field map)
The detectors are copied from SoLID BaBar, but with longer Calorimeter.
SIDIS CLEO | Z range (cm) | Z center (cm) | Z length (cm) | R range (cm) | R length (cm) |
---|---|---|---|---|---|
target | -370 - -330 | -350 | 40 | 0 - 1 | 1 |
GEM | |||||
largeangle Calorimeter | -65.5 - -15.5 | -40.5 | 50 | 82 - 141 | 59 |
lightgas Cherenkov | 97 - 225 - 301 | 161, 263 | 204 | 67 - 160 - 265 | 198 |
SC | 303.75 - 304.25 | 304 | 0.5 | 95 - 177 | 82 |
heavygas Cherenkov | 306 - 396 | 351 | 90 | 96- 265 | 169 |
MRPC | 397 - 399 | 398 | 2 | 115 - 195 | 90 |
forwardangle Calorimeter | 400 - 450 | 425 | 50 | 120 - 202 | 95 |
empty space at back | 450 - 480 | 465 | 30 |
PVDIS CLEO | Z range (cm) | Z center (cm) | Z length (cm) | R range (cm) | R length (cm) |
---|---|---|---|---|---|
target | -10 - 30 | 10 | 40 | ||
GEM #1 #2 | |||||
Cherenkov | 200 - 225 - 301 | 212.5, 262.5 | 25, 75 | 61 - 260 | 199 |
GEM #3 | 305.52 - 306.48 | 306 | 0.96 | 105 -200 | 95 |
GEM #4 | 320.52 - 321.48 | 321 | 0.96 | 115 -215 | 100 |
forwardangle Calorimeter | 325 - 375 | 350 | 50 | 110 - 265 | 155 |
empty space at back | 375 - 405 | 390 | 30 |
SoLID BaBar (based on BABARv4 field map)
The detectors converted from comgeant configuration at the proposal stage, then modified with longer Cherenkov.
SIDIS BaBar | Z range (cm) | Z center (cm) | Z length (cm) | R range (cm) | R length (cm) |
---|---|---|---|---|---|
target | -370 - -330 | -350 | 40 | 0 - 1 | 1 |
GEM | |||||
largeangle Calorimeter | -65.5 - -35.5 | -50.5 | 30 | 82 - 141 | 59 |
lightgas Cherenkov | 97 - 225 - 301 | 161, 263 | 204 | 67 - 160 - 265 | 198 |
SC | 303.75 - 304.25 | 304 | 0.5 | 95 - 177 | 82 |
heavygas Cherenkov | 306 - 396 | 351 | 90 | 96- 265 | 169 |
MRPC | 397 - 399 | 398 | 2 | 115 - 195 | 90 |
forwardangle Calorimeter | 400 - 430 | 415 | 30 | 120 - 202 | 95 |
PVDIS BaBar | Z range (cm) | Z center (cm) | Z length (cm) | R range (cm) | R length (cm) |
---|---|---|---|---|---|
target | -10 - 30 | 10 | 40 | ||
GEM #1 #2 | |||||
Cherenkov | 200 - 225 - 301 | 212.5, 262.5 | 25, 75 | 61 - 260 | 199 |
GEM #3 | 305.52 - 306.48 | 306 | 0.96 | 105 -200 | 95 |
GEM #4 | 320.52 - 321.48 | 321 | 0.96 | 115 -215 | 100 |
forwardangle Calorimeter | 325 - 375 | 350 | 50 | 110 - 265 | 155 |