Difference between revisions of "Polhe3 electronics list 2014"
From Hall A Wiki
(→future list) |
(→current list) |
||
Line 4: | Line 4: | ||
2 KEPCO powersupply (good for voltage mode) | 2 KEPCO powersupply (good for voltage mode) | ||
− | + | 1 HP 6675A powersupply (good for current mode) | |
2 DS345 function generator (control offset) '''need 1 more DS345 to have three coil at same time, we have 1 spare''' | 2 DS345 function generator (control offset) '''need 1 more DS345 to have three coil at same time, we have 1 spare''' | ||
1 wavetek80 function generator (trigger) | 1 wavetek80 function generator (trigger) | ||
3 Fluke meter (monitor) | 3 Fluke meter (monitor) | ||
1 rotation box | 1 rotation box | ||
− | 1 | + | 1 DC power supply Agilent E3634A(correction coil) |
RF (2 set RF) | RF (2 set RF) | ||
Line 20: | Line 20: | ||
2 SR560 preamplifier (pickup signal) '''need 1 SR560 to have three sets, we have 3 spare''' | 2 SR560 preamplifier (pickup signal) '''need 1 SR560 to have three sets, we have 3 spare''' | ||
− | + | 2 SR844 lockin amplifier (collect signal) | |
− | 1 power | + | 1 DC power source 2040A (for convection) |
pNMR (1 set) | pNMR (1 set) | ||
Line 30: | Line 30: | ||
2 SR560 preamplifier (pickup signal) | 2 SR560 preamplifier (pickup signal) | ||
2 switch | 2 switch | ||
− | 1 DC | + | 1 DC power supply HY3005F-3 with two output (for switch) |
1 mixer | 1 mixer | ||
− | + | 1 Tektronik TDS 1002B oscilloscope | |
1 DAQ card | 1 DAQ card | ||
Line 41: | Line 41: | ||
1 HP E4400B function generator (generate signal) | 1 HP E4400B function generator (generate signal) | ||
1 PerkinElmer 7265 lockin amplifier (collect signal) | 1 PerkinElmer 7265 lockin amplifier (collect signal) | ||
− | 1 Amplifier | + | 1 2100-L RF power Amplifier |
1 PI box '''another box is under making''' | 1 PI box '''another box is under making''' | ||
+ | |||
+ | Density | ||
+ | 1 Wavemeter WA-1100 Burleigh | ||
+ | 1 tunable-diode-laser | ||
+ | 1 3501 optical chopper | ||
+ | 1 7265 DSP lock-in amplifier | ||
spare | spare | ||
Line 50: | Line 56: | ||
2 HP 34401A multimeter | 2 HP 34401A multimeter | ||
2 KEPCO powersupply (good for voltage mode) | 2 KEPCO powersupply (good for voltage mode) | ||
− | 1 lock-in amplifier SR844 | + | 1 lock-in amplifier SR844 (at UNH) |
− | 1 lock-in amplifier | + | 1 lock-in amplifier SR830 |
'''1 HP E4400B (at UNH)''' | '''1 HP E4400B (at UNH)''' | ||
− | + | 1 SR620 | |
3 SR560 Preamplifier | 3 SR560 Preamplifier | ||
1 DS345 | 1 DS345 | ||
− | + | 1 6675A power supply (bought in Aug 2015) | |
+ | 1 6673A (old) | ||
+ | 1 DC power supply Agilent E3634A | ||
+ | 2 PI box | ||
broken | broken | ||
1 DS345 | 1 DS345 | ||
− | |||
1 EPR/density lockin? need check again | 1 EPR/density lockin? need check again | ||
Revision as of 16:35, 19 November 2015
current list
holding field (3 set)
2 KEPCO powersupply (good for voltage mode) 1 HP 6675A powersupply (good for current mode) 2 DS345 function generator (control offset) need 1 more DS345 to have three coil at same time, we have 1 spare 1 wavetek80 function generator (trigger) 3 Fluke meter (monitor) 1 rotation box 1 DC power supply Agilent E3634A(correction coil)
RF (2 set RF)
1 HP 3324 function generator (RF signal) 1 AG amplifier (RF amplifier) 1 capacitor box (match RF coil impedance)
NMR (3 sets pickup)
2 SR560 preamplifier (pickup signal) need 1 SR560 to have three sets, we have 3 spare 2 SR844 lockin amplifier (collect signal) 1 DC power source 2040A (for convection)
pNMR (1 set)
1 wavetek80 function generator(trigger) 1 DS345 function generator(RF signal) 1 DS345 function generator (reference signal) 2 SR560 preamplifier (pickup signal) 2 switch 1 DC power supply HY3005F-3 with two output (for switch) 1 mixer 1 Tektronik TDS 1002B oscilloscope 1 DAQ card
EPR (1 set)
1 DS345 function generator(generate signal) 1 SR620 (counter) 1 HP E4400B function generator (generate signal) 1 PerkinElmer 7265 lockin amplifier (collect signal) 1 2100-L RF power Amplifier 1 PI box another box is under making
Density
1 Wavemeter WA-1100 Burleigh 1 tunable-diode-laser 1 3501 optical chopper 1 7265 DSP lock-in amplifier
spare
1 HP 3324 function generator 2 AG amplifier 2 HP 34401A multimeter 2 KEPCO powersupply (good for voltage mode) 1 lock-in amplifier SR844 (at UNH) 1 lock-in amplifier SR830 1 HP E4400B (at UNH) 1 SR620 3 SR560 Preamplifier 1 DS345 1 6675A power supply (bought in Aug 2015) 1 6673A (old) 1 DC power supply Agilent E3634A 2 PI box
broken
1 DS345 1 EPR/density lockin? need check again
future list
1 untrasonic gauge? 3197$ 1 power supply for tranverse coil (current driven) 1 power supply for vertical coil (current driven)? if we can, we can get the high stable one for pulse nmr study broken repair