Difference between revisions of "Spectrometer Optics 2pass"
From Hall A Wiki
Line 79: | Line 79: | ||
<td>2.0</td> | <td>2.0</td> | ||
<td>1.3106</td> | <td>1.3106</td> | ||
− | <td> | + | <td>52.5</td> |
<td>-4</td> | <td>-4</td> | ||
<td></td> | <td></td> | ||
Line 87: | Line 87: | ||
<td>2.0</td> | <td>2.0</td> | ||
<td>1.2854</td> | <td>1.2854</td> | ||
− | <td> | + | <td>52.5</td> |
<td>-2</td> | <td>-2</td> | ||
<td></td> | <td></td> | ||
Line 95: | Line 95: | ||
<td>2.0</td> | <td>2.0</td> | ||
<td>1.2602</td> | <td>1.2602</td> | ||
− | <td> | + | <td>52.5</td> |
<td>0</td> | <td>0</td> | ||
<td></td> | <td></td> | ||
Line 103: | Line 103: | ||
<td>2.0</td> | <td>2.0</td> | ||
<td>1.2350</td> | <td>1.2350</td> | ||
− | <td> | + | <td>52.5</td> |
<td>+2</td> | <td>+2</td> | ||
<td></td> | <td></td> | ||
Line 111: | Line 111: | ||
<td>2.0</td> | <td>2.0</td> | ||
<td>1.2098</td> | <td>1.2098</td> | ||
− | <td> | + | <td>52.5</td> |
<td>+4</td> | <td>+4</td> | ||
<td></td> | <td></td> | ||
Line 136: | Line 136: | ||
<td>2.0</td> | <td>2.0</td> | ||
<td>1.26022</td> | <td>1.26022</td> | ||
− | <td> | + | <td>52.5</td> |
<td>1.40</td> | <td>1.40</td> | ||
<td></td> | <td></td> |
Revision as of 19:35, 17 April 2015
Contents
Procedure without Sieve-slit
- Time estimate: 4 hours
* Take a run at the following kinematics without the sieve-slit collimator. * Start with initial right HRS spectrometer tune with the SOS quad in place of right Q1. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Electron rates assume 5 carbon foils, 5 mSr acceptance, and 8% delta acceptance. * A GMp expert will check the data quality and decide, if the right HRS tune needs to be adjusted to change the size of the acceptance. * This process will be repeated until the spectrometer tune is satisfactory.
Ebeam [GeV] | P0 [GeV/c] | θe [deg] | Q2 [GeV2] | W [GeV] | Rate [Hz] at 5 μA | minutes for 23k events at 5 μA |
2.0 | 0.75 | 52.5 | 1.17 | 1.433 | 15.5 | 25 |
Procedure with Sieve-slit
- Time estimate: 3 hours
* Trained personnel will be required to install the 1-inch tungsten sieve-slit collimator onto the front face of the HRS. * Take a sieve slit run with the multi-foil carbon target for the inelastic kinematics in the table. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Repeat the above with the beam position shifted so that you see a vertical shift by one row. * Rates assume 5 carbon foils, only 25 out of 63 sieve holes have events (~ 0.265 mSr acceptance), and 8% delta acceptance.
Ebeam [GeV] | P0 [GeV/c] | θe [deg] | Q2 [GeV2] | W [GeV] | Rate [Hz] at 5 μA | hours for 100k events at 5 μA |
2.0 | 0.75 | 52.5 | 1.17 | 1.443 | 0.8 | 34 |
Delta Scan with Proton Elastic
- Time estimate: 1-2 hours
* Trained personnel will be required to remove the 1-inch lead sieve-slit collimator onto the front face of the HRS. * Take a run with the 15 cm liquid hydrogen target for the elastic kinematics in the table. * There will be a time lapse between settings until the right dipole reaches the desired momentum and is stable. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
Ebeam (GeV) | k' (GeV) | θe (deg) | ΔP (%) | Rate [Hz] at 20 μA | minutes for 10k events at 20 μA |
2.0 | 1.3106 | 52.5 | -4 | ||
2.0 | 1.2854 | 52.5 | -2 | ||
2.0 | 1.2602 | 52.5 | 0 | ||
2.0 | 1.2350 | 52.5 | +2 | ||
2.0 | 1.2098 | 52.5 | +4 |
Elastic from Hydrogen
- Time estimate: 1-2 hours
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Elastic electron-proton measurement. Assuming a 15 cm LH2 target, a spectrometer acceptance of 5 msr and elastic from Eric's rate program
to compute the cross-section.
Ebeam (GeV) | k' (GeV) | θe (deg) | Q2 (GeV2) | Rate [Hz] at 20 μA | minutes for 40k events at 20 μA |
2.0 | 1.26022 | 52.5 | 1.40 |