Difference between revisions of "Production Run Plan R-HRS"
From Hall A Wiki
(→Proton Elastic Kinematics) |
|||
Line 51: | Line 51: | ||
<td>Q<SUP>2</SUP> [GeV<SUP>2</SUP>]</td> | <td>Q<SUP>2</SUP> [GeV<SUP>2</SUP>]</td> | ||
<td> Electron Rate [Hz] at 20 μA</td> | <td> Electron Rate [Hz] at 20 μA</td> | ||
− | <td> | + | <td> days at 20 μA</td> |
</tr> | </tr> | ||
<tr> | <tr> | ||
<td>15 cm LH2</td> | <td>15 cm LH2</td> | ||
<td>2 x 2 mm<sup>2</sup></td> | <td>2 x 2 mm<sup>2</sup></td> | ||
− | <td> | + | <td>8.841</td> |
− | <td> | + | <td>2.101</td> |
<td>48.74</td> | <td>48.74</td> | ||
− | <td> | + | <td>12.65</td> |
− | <td> | + | <td>0.018</td> |
− | <td> | + | <td>21 (for 32k events)</td> |
</tr> | </tr> | ||
<tr> | <tr> |
Revision as of 23:50, 12 February 2016
Proton Elastic Kinematics
- 2nd Pass (E = 4.5 GeV) Time estimate: 15 hours
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Elastic electron rates assume 20 μA on 15 cm LH2 target, 5 mSr acceptance. * A GMp expert will check the data quality.
Target | Raster | Ebeam [GeV] | P0 [GeV/c] | θe [deg] | Q2 [GeV2] | Electron Rate [Hz] at 20 μA | hours at 20 μA |
15 cm LH2 | 2 x 2 mm2 | 4.481 | 1.706 | 48.74 | 5.21 | 2.4 | 12 (for 100k events) |
15 cm Dummy | 2 x 2 mm2 | 4.481 | 1.706 | 48.74 | 5.21 | 0.4 | 2.5 (for 3.6k events) |
- 4th Pass (E = 8.8 GeV) Time estimate: 15 hours
Target | Raster | Ebeam [GeV] | P0 [GeV/c] | θe [deg] | Q2 [GeV2] | Electron Rate [Hz] at 20 μA | days at 20 μA |
15 cm LH2 | 2 x 2 mm2 | 8.841 | 2.101 | 48.74 | 12.65 | 0.018 | 21 (for 32k events) |
15 cm Dummy | 2 x 2 mm2 | 4.481 | 1.706 | 48.74 | 5.21 | 0.4 | 2.5 (for 3.6k events) |