Difference between revisions of "Spectrometer Optics First pass 48p8d"
From Hall A Wiki
(→Dummy Target Runs) |
(→Dummy Target Runs) |
||
Line 195: | Line 195: | ||
<td>ΔP (%)</td> | <td>ΔP (%)</td> | ||
<td>Rate [Hz] at 20 μA</td> | <td>Rate [Hz] at 20 μA</td> | ||
− | + | <td>hours at 20 μA</td> | |
</tr> | </tr> | ||
<tr> | <tr> | ||
Line 203: | Line 203: | ||
<td>48.74</td> | <td>48.74</td> | ||
<td>0</td> | <td>0</td> | ||
− | <td> | + | <td>13.2</td> |
− | <td> | + | <td>2 </td> |
</tr> | </tr> | ||
</table> | </table> |
Revision as of 20:22, 22 February 2016
Contents
Procedure with Sieve-slit
- Time estimate: 12 hours
* Trained personnel will be required to install the 1-inch tungsten sieve-slit collimator onto the front face of the HRS. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Take sieve-slit runs with the multi-foil carbon target (optics) for the inelastic kinematics in the table. * Electron rates assume 5 carbon foils, only 37 out of 155 sieve holes per foil have events (~ 0.4 mSr acceptance), and 8% delta acceptance. * Electron rates assume 2 aluminum foils, only 43 out of 155 sieve holes per foil have events (~ 0.47 mSr acceptance), and 8% delta acceptance. * Electron rates assume 15 cm LH2 target, only 45 out of 155 sieve holes have events (~ 0.49 mSr acceptance), and 8% delta acceptance. * Before moving on to the next target, a GMp expert will determine online how many good electron events have been collected.
Target | Ebeam [GeV] | P0 [GeV/c] | Raster | θe [deg] | Q2 [GeV2] | W [GeV] | Rate [Hz] at 20 μA | hours at 20 μA | Good Electrons |
Optics | 2.301 | 0.75 | Off | 48.74 | 1.18 | 1.617 | 5.6 | 5 | 100k events |
4 cm Dummy | 2.301 | 0.75 | 1x1 mm2 | 48.74 | 1.18 | 1.617 | 3.5 | 4 | 50k events |
Carbon single foil | 2.301 | 0.75 | Off | 48.74 | 1.18 | 1.617 | 2.2 | 1.7 | 13.7k events |
15 cm LH2 | 2.301 | 0.75 | 2x2 mm2 | 48.74 | 1.18 | 1.617 | 20.0 | 1.7 | 122k events |
- Wire Target Run
* After the above runs are completed, ask for the target group to insert the wire-target (we are not allowed to do it). * Target expert (Dave Meekins) will need to go to the Hall and manually move the target in position, so ask for controlled access before starting this step * Take a run with the wire target. * Electron rates assume 200 μm of tungsten, the rate is only for the central hole of the sieve slit (~ 0.023 mSr acceptance), and 8% delta acceptance. * A GMp expert will determine when enough good electron events have been collected.
Target | Ebeam [GeV] | P0 [GeV/c] | θe [deg] | Q2 [GeV2] | W [GeV] | Rate [Hz] at 20 μA | hours at 20 μA |
200 μm tungsten wire | 2.301 | 0.75 | 48.74 | 1.18 | 1.617 | 0.3 | 1 (for 1k events) |
- After finishing this step, ask for Controlled access so that target expert can move the wire-target out of the way
Delta Scan with Proton Elastic
- Time estimate: 3 hours
* Trained personnel will be required to remove the 1-inch tungsten sieve-slit collimator from the front face of the HRS. * Take runs with the 15 cm liquid hydrogen target for the elastic kinematics in the table. * There will be a time lapse between settings until the right dipole reaches the desired momentum and is stable. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Rate estimates only include elastic electrons and does not include rate from inelastic events or from the target endcaps. * The Q2 for these settings is 1.96 GeV2.
Ebeam (GeV) | k' (GeV) | Raster | θe (deg) | ΔP (%) | Rate [Hz] at 20 μA | minutes at 20 μA | Good Electrons |
2.301 | 1.304 | 2x2 mm2 | 48.74 | -4 | 176 | 40 | 422k events |
2.301 | 1.279 | 2x2 mm2 | 48.74 | -2 | 176 | 40 | 422k events |
2.301 | 1.254 | 2x2 mm2 | 48.74 | 0 | 176 | 100 | 1M events |
2.301 | 1.229 | 2x2 mm2 | 48.74 | +2 | 176 | 40 | 422k events |
2.301 | 1.203 | 2x2 mm2 | 48.74 | +4 | 176 | 40 | 422k events |
Dummy Target Runs
- Go back to the ΔP = 0% elastic setting. Make sure the R-HRS P0 = 1.254 GeV.
- Move the target to "Dummy"
- Take R-HRS run with same setting as previous step. We need at least 100 k events.
- Take data with this setting for 2 hours
Ebeam (GeV) | k' (GeV) | Raster | θe (deg) | ΔP (%) | Rate [Hz] at 20 μA | hours at 20 μA |
2.301 | 1.254 | 2x2 mm2 | 48.74 | 0 | 13.2 | 2 |
- Move the target to "Dummy"
- Take R-HRS run with same setting as previous step. We need at least 200 K events.
Procedure without Sieve-slit
- Time estimate: 1 hour
* Take a run at the following kinematics without the sieve-slit collimator. * Start with initial right HRS spectrometer tune with the SOS quad in place of right Q1. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Electron rates assume 5 carbon foils or 2 Al dummy foils, 5 mSr acceptance, and 8% delta acceptance. * A GMp expert will check the data quality.
Target | Ebeam [GeV] | P0 [GeV/c] | Right Q1 Current [A] | θe [deg] | Q2 [GeV2] | W [GeV] | Rate [Hz] at 20 μA | minutes for 50k events at 20 μA |
Optics | 2.301 | 0.75 | 153.36 | 48.74 | 1.18 | 1.617 | 70.5 | 12 |
4 cm Dummy | 2.301 | 0.75 | 153.36 | 48.74 | 1.18 | 1.617 | 37.4 | 22 |