Difference between revisions of "Make sure laser flipping is on"

From Hall A Wiki
Jump to: navigation, search
Line 10: Line 10:
  
 
Flags:
 
Flags:
[1] "flip" means cycle the laser on and off.
+
 
[2] bcm_threshold: minimum beam current for script to execute  
+
# "flip" means cycle the laser on and off.
[3] time_off: time for laser off period in seconds
+
# bcm_threshold: minimum beam current for script to execute  
[4] time_on: time for laser on in seconds
+
# time_off: time for laser off period in seconds
[5] power_threshold: cavity power threshold above which the time_on counter begins
+
# time_on: time for laser on in seconds
 +
# power_threshold: cavity power threshold above which the time_on counter begins
  
 
I typically run the script as follows:
 
I typically run the script as follows:
  
 
cavity_C_gaskell flip -1 30 90 100
 
cavity_C_gaskell flip -1 30 90 100

Revision as of 14:22, 29 March 2016

The script that cycles the Compton laser lock on and off should be run from the vncserver on compton-old (compton-old:005). I typically run it in a terminal from the bottom left workspace.

The script is located in:

/home/compton/gaskelld/cavity_script

And should be run as follows:

cavity_C_gaskell flip <bcm_threshold> <time_off> <time_on> <power_threshold>

Flags:

  1. "flip" means cycle the laser on and off.
  2. bcm_threshold: minimum beam current for script to execute
  3. time_off: time for laser off period in seconds
  4. time_on: time for laser on in seconds
  5. power_threshold: cavity power threshold above which the time_on counter begins

I typically run the script as follows:

cavity_C_gaskell flip -1 30 90 100