Difference between revisions of "Laser"

From Hall A Wiki
Jump to: navigation, search
(Power Test Result of COMET Lasers =)
(Rutgers COMET Laser)
Line 81: Line 81:
 
! Wavelength FWHM (mn)
 
! Wavelength FWHM (mn)
 
|-
 
|-
|10 |1.66 |1.71 |1.34 |794.79 |0.58
+
|10
 +
|1.66
 +
|1.71
 +
|1.34
 +
|794.79
 +
|0.58
 +
|-
 
|15 |1.72 |2.18 |5.82 |794.83 |0.50
 
|15 |1.72 |2.18 |5.82 |794.83 |0.50
 +
|-
 
|20 |1.78 |2.57 |10.5 |794.88 |0.51
 
|20 |1.78 |2.57 |10.5 |794.88 |0.51
 +
|-
 
|25 |1.84 |2.77 |15.1 |794.91 |0.53
 
|25 |1.84 |2.77 |15.1 |794.91 |0.53
 +
|-
 
|30 |1.90 |3.31 |19.7 |794.94 |0.57
 
|30 |1.90 |3.31 |19.7 |794.94 |0.57
 +
|-
 
|35 |1.95 |4.18 |24.3 |795.01 |0.57
 
|35 |1.95 |4.18 |24.3 |795.01 |0.57
 +
|-
 
|40 |2.01 |4.95 |28.6 |795.06 |0.62
 
|40 |2.01 |4.95 |28.6 |795.06 |0.62
|44 |2.05 |5.53 |32.1 |795.11 |0.64 |}
+
|-
 +
|44 |2.05 |5.53 |32.1 |795.11 |0.64  
 +
|}

Revision as of 00:22, 21 October 2008

Single FAP Lasers

DUO FAP Lasers

COMET Lasers

Power Test Result of COMET Lasers =

Test Condition

  • Room Temperature: 22.9 C
  • Diode Temperature: 20.0 C

W&M COMET Laser

Diode Current (I) Driving Voltage (V) Cooling Current (I) Laser Power (W) Central Wavelength (nm) Wavelength FWHM (mn)
10 1.67 1.56 2.67 794.84 0.55
15 1.74 1.99 7.18 794.90 0.53
20 1.80 2.45 11.9 794.98 0.52
25 1.87 2.96 16.5 795.03 0.50
30 1.93 3.56 21.1 795.09 0.52
35 1.99 4.29 25.6 795.15 0.56
40 2.05 5.18 30.3 795.22 0.60

Rutgers COMET Laser

Diode Current (I) Driving Voltage (V) Cooling Current (I) Laser Power (W) Central Wavelength (nm) Wavelength FWHM (mn)
10 1.66 1.71 1.34 794.79 0.58
1.72 |2.18 |5.82 |794.83 |0.50
1.78 |2.57 |10.5 |794.88 |0.51
1.84 |2.77 |15.1 |794.91 |0.53
1.90 |3.31 |19.7 |794.94 |0.57
1.95 |4.18 |24.3 |795.01 |0.57
2.01 |4.95 |28.6 |795.06 |0.62
2.05 |5.53 |32.1 |795.11 |0.64