Difference between revisions of "Fall 2016 calorimeter calibration (elastic)"
From Hall A Wiki
Line 4: | Line 4: | ||
Need to remove the plastic shield. <br> | Need to remove the plastic shield. <br> | ||
− | Calorimeter-Target distance = | + | Calorimeter-Target distance =6.0m<br> |
LH2 target, unrastered beam (which means beam current at less than 5 uA). <br> | LH2 target, unrastered beam (which means beam current at less than 5 uA). <br> | ||
LHRS in positive polarity.<br> | LHRS in positive polarity.<br> | ||
Open LHRS collimator<br> | Open LHRS collimator<br> | ||
DAQ: DVCS config, trigger is S0+S2, autovalidation.<br> | DAQ: DVCS config, trigger is S0+S2, autovalidation.<br> | ||
− | angle<SUB>LHRS</SUB>= | + | angle<SUB>LHRS</SUB>= 32.50 [deg]<br> |
− | momentum<SUB> LHRS</SUB>= | + | momentum<SUB> LHRS</SUB>= 3.0 GeV<br> |
beam energy= 6.4 GeV<br> | beam energy= 6.4 GeV<br> | ||
− | We will take about 1 hour beam with three calorimeter angles: | + | We will take about 1 hour beam with three calorimeter angles: 21.4, 22.7 and 24.0 deg. |
[[Image:Elastic_kinematic_4.5.jpg| 1000px]] | [[Image:Elastic_kinematic_4.5.jpg| 1000px]] |
Revision as of 11:43, 20 September 2016
Back to [Run Plan DVCS 3 ]
This is in progress (09-20-16 contact J. Roche)
Need to remove the plastic shield.
Calorimeter-Target distance =6.0m
LH2 target, unrastered beam (which means beam current at less than 5 uA).
LHRS in positive polarity.
Open LHRS collimator
DAQ: DVCS config, trigger is S0+S2, autovalidation.
angleLHRS= 32.50 [deg]
momentum LHRS= 3.0 GeV
beam energy= 6.4 GeV
We will take about 1 hour beam with three calorimeter angles: 21.4, 22.7 and 24.0 deg.