Difference between revisions of "Fall 2016 LHRS optic plans"

From Hall A Wiki
Jump to: navigation, search
(Step L2: Delta Scan with Proton Elastic (without sieve slit))
(Step L2: Delta Scan with Proton Elastic (without sieve slit))
Line 49: Line 49:
 
<br>
 
<br>
  
==== Step L2: Delta Scan with Proton Elastic (without sieve slit)====
+
==== Step L2: Delta Scan with Proton Elastic (with sieve slit)====
 
* Time estimate: 3-4 hours
 
* Time estimate: 3-4 hours
  
  * Trained personnel will be required to remove the 1-inch tungsten sieve-slit collimator from the front face of the HRS.
+
  * Keep the 1-inch tungsten sieve-slit collimator on the front face of the left HRS.
 
  * Take runs with the 15 cm liquid hydrogen target for the elastic kinematics in the table.
 
  * Take runs with the 15 cm liquid hydrogen target for the elastic kinematics in the table.
  * There will be a time lapse between settings until the right dipole reaches the desired momentum and is stable.
+
  * Wait until the left dipole reaches the desired momentum and is stable.
 
  * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
 
  * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
 
  * Rate estimates only include elastic electrons and does not include rate from inelastic events or from the target endcaps.  
 
  * Rate estimates only include elastic electrons and does not include rate from inelastic events or from the target endcaps.  
  * The Q<sup>2</sup> for these settings is 1.86 GeV<sup>2</sup>.
+
  * The Q<sup>2</sup> for these settings is 0.41 GeV<sup>2</sup>.
  
 
<table border="1"  style="width:80%">
 
<table border="1"  style="width:80%">

Revision as of 18:03, 8 October 2016

Step L1: Procedure with Sieve-slit

  • Time estimate: 1 hour
* Trained personnel will be required to install the 1-inch tungsten sieve-slit collimator onto the front face of the HRS.
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
* Take sieve-slit runs with the multi-foil carbon target (optics) for the inelastic kinematics in the table.
* Electron rates assume 9 carbon foils, only 37 out of 155 sieve holes per foil have events (~ 0.41 mSr acceptance), and 8% delta acceptance.
* Electron rates assume 15 cm LH2 target, only 45 out of 155 sieve holes have events (~ 0.49 mSr acceptance), and 8% delta acceptance.
* Adjust the prescale factors to keep the DAQ deadtime below 10%.
* Before moving on to the next target, a GMp expert will determine online how many good electron events have been collected. 
Target Ebeam [GeV] P0 [GeV/c] Raster θe [deg] Q2 [GeV2] W [GeV] Rate [Hz] at 60 μA minutes at 60 μA Good Electrons
Optics 2.217 1.0 Off 17.5 0.20 1.72 540 32 1M events
15 cm LH2 2.217 1.0 3x3 mm2 17.5 0.20 1.72 4600 10.0 2.7M events


Step L2: Delta Scan with Proton Elastic (with sieve slit)

  • Time estimate: 3-4 hours
* Keep the 1-inch tungsten sieve-slit collimator on the front face of the left HRS.
* Take runs with the 15 cm liquid hydrogen target for the elastic kinematics in the table.
* Wait until the left dipole reaches the desired momentum and is stable.
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
* Rate estimates only include elastic electrons and does not include rate from inelastic events or from the target endcaps. 
* The Q2 for these settings is 0.41 GeV2.
Ebeam (GeV) k' (GeV) Raster θe (deg) ΔP (%) Rate [Hz] at 10 μA minutes at 10 μA Good Electrons
2.217 2.078 3x3 mm2 17.5 -4 650 10 390k events
2.217 2.038 3x3 mm2 17.5 -2 650 10 390k events
2.217 1.998 3x3 mm2 17.5 0 650 20 780k events
2.217 1.958 3x3 mm2 17.5 +2 650 10 390k events
2.217 1.918 3x3 mm2 17.5 +4 650 10 390k events


Step L3: Dummy Target Runs

  • Go back to the ΔP = 0% elastic setting. Make sure the L-HRS P0 = 1.228 GeV.
  • Move the target to "15 cm Dummy"
  • Take R-HRS run with same setting as previous step.
  • Take data with this setting for 1 hour


Ebeam (GeV) k' (GeV) Raster θe (deg) ΔP (%) Rate [Hz] at 40 μA hours at 40 μA Good Electrons
2.217 1.228 3x3 mm2 17.5 0 19.5 1 70k events


Step L4: Procedure without Sieve-slit

  • Time estimate: 1 hour
* Take a run at the following kinematics without the sieve-slit collimator.
* If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure.
* Electron rates assume 9 carbon foils or 1 single carbon foil, 5 mSr acceptance, and 8% delta acceptance.
* A GMp expert will check the data quality.

Target Ebeam [GeV] P0 [GeV/c] Right Q1 Current [A] θe [deg] Q2 [GeV2] W [GeV] Rate [Hz] at 60 μA minutes at 60 μA Good Electrons
Optics 2.217 1.0 173.808 17.5 1.51 1.287 250 15 220k events
Single Carbon 2.217 1.0 173.808 17.5 1.51 1.287 56 15 50k events