Difference between revisions of "Dec 3, 2018"
Line 35: | Line 35: | ||
Minutes: | Minutes: | ||
+ | Simona | ||
+ | Magnet moving to Hall perhaps tomorrow. | ||
+ | Yves has a rough plan for determining misalignment of magnet. Plan involves taking data at +/-4T fields. Need 1 minute of data at several points. Requires 3.5 hours. | ||
+ | Simona working on HV controls for polarimeter. 24 V power supply on rate required replacement. Replacement complete and HV controls works. PMT voltage ramp now works. | ||
+ | No update on O-rings. | ||
+ | |||
+ | Bill | ||
+ | New comparison of G3/G4 better with G4 lead included. Azz still 0.4% different. | ||
+ | Eric will verify using ideal quad fields in G3/G4 Azz comparison. | ||
+ | |||
+ | Erik | ||
+ | Quad maps show significant focusing difference at dipole exit/detector. Will investigate quantitative difference in Azz at PREX CREX solutions. Will also see difference in quads scans due to new TOSCA maps. | ||
Line 40: | Line 52: | ||
Attendees: | Attendees: | ||
− | + | Bill, Simona, Dave, Don, Jim, Erik, Kent, Sanghwa | |
Excused: | Excused: |
Revision as of 17:28, 3 December 2018
Back to Main Page >> Moller Page >> Moller Weekly Meeting Index
previous meeting << >> following meeting
Original Moller Polarimeter Page
Connection details:
Meeting URL
https://bluejeans.com/149766532
Meeting ID 149 766 532
US toll free phone 1.888.240.2560
Dial in, type in the meeting ID and then press ##
Agenda
- Update on hardware and software -Simona M
- GEANT4 simulation update -Eric K
- GEANT3 simulation update -Bill H slides
Minutes: Simona Magnet moving to Hall perhaps tomorrow. Yves has a rough plan for determining misalignment of magnet. Plan involves taking data at +/-4T fields. Need 1 minute of data at several points. Requires 3.5 hours. Simona working on HV controls for polarimeter. 24 V power supply on rate required replacement. Replacement complete and HV controls works. PMT voltage ramp now works. No update on O-rings.
Bill New comparison of G3/G4 better with G4 lead included. Azz still 0.4% different. Eric will verify using ideal quad fields in G3/G4 Azz comparison.
Erik Quad maps show significant focusing difference at dipole exit/detector. Will investigate quantitative difference in Azz at PREX CREX solutions. Will also see difference in quads scans due to new TOSCA maps.
Attendees: Bill, Simona, Dave, Don, Jim, Erik, Kent, Sanghwa