Difference between revisions of "Eed Target Calibration List"

From Hall A Wiki
Jump to: navigation, search
(Field Setting History)
(May 26, 2009, 11:36)
Line 74: Line 74:
 
* Field Direction: Transverse -
 
* Field Direction: Transverse -
 
* Pumping Direction: Transverse +
 
* Pumping Direction: Transverse +
* Small Correction Coil: 0.9 A
+
* Small Correction Coil: 0.5 A
 
* Large Correction Coil: OFF
 
* Large Correction Coil: OFF
 
* BigBite Current: 518 A
 
* BigBite Current: 518 A

Revision as of 01:12, 31 May 2009

Cell History

MOSS: May 12 - Jun 20 2009

  • Cell Name: MOSS
  • He3 Density (amg): 7.962
  • N2 Density (amg): 0.1132
  • Vpc (cc): 184.13
  • Vtt (cc): 6.54
  • Vtc (cc): 78.23https://hallaweb.jlab.org/wiki/index.php?title=Eed_Target_Calibration_List&action=edit
  • NMR Lock-in gain: x5, x2 of transverse pickup coil at some point
  • Data : click me

Field Setting History

May 12, 2009, 05:57

  • Field Strength: 25 Gaus
  • Field Direction: Longitudinal -
  • Pumping Direction: Longitudinal +
  • Small Correction Coil: OFF
  • Large Correction Coil: OFF
  • BigBite Current: 518 A
  • BigBite Angle: 75 degrees
  • Halog: click me

May 19, 2009, 13:00

  • Field Strength: 25 Gaus
  • Field Direction: Transverse -
  • Pumping Direction: Transverse +
  • Small Correction Coil: OFF
  • Large Correction Coil: OFF
  • BigBite Current: 518 A
  • BigBite Angle: 75 degrees
  • Halog: click me

May 20, 2009, 18:58

  • Field Strength: 25 Gaus
  • Field Direction: Transverse +
  • Pumping Direction: Transverse -
  • Small Correction Coil: OFF
  • Large Correction Coil: OFF
  • BigBite Current: 518 A
  • BigBite Angle: 75 degrees
  • Halog: click me

May 21, 2009, 12:54

  • Field Strength: 25 Gaus
  • Field Direction: Transverse +
  • Pumping Direction: Transverse -
  • Small Correction Coil: 0.5A
  • Large Correction Coil: OFF
  • BigBite Current: 518 A
  • BigBite Angle: 75 degrees
  • Halog: click me

May 24, 2009, 18:51

  • Field Strength: 25 Gaus
  • Field Direction: Transverse -
  • Pumping Direction: Transverse +
  • Small Correction Coil: 0.5 A
  • Large Correction Coil: OFF
  • BigBite Current: 518 A
  • BigBite Angle: 75 degrees
  • Halog: click me

May 26, 2009, 11:36

  • Field Strength: 25 Gaus
  • Field Direction: Transverse -
  • Pumping Direction: Transverse +
  • Small Correction Coil: 0.5 A
  • Large Correction Coil: OFF
  • BigBite Current: 518 A
  • BigBite Angle: 82 degrees
  • Halog: click me

May 26, 2009, 18:51

  • Field Strength: 25 Gaus
  • Field Direction: Transverse -
  • Pumping Direction: Transverse +
  • Small Correction Coil: 0.9 A
  • Large Correction Coil: OFF
  • BigBite Current: 518 A
  • BigBite Angle: 82 degrees
  • Halog: click me

May 28, 2009, 12:03

  • Field Strength: 25 Gaus
  • Field Direction: Transverse +
  • Pumping Direction: Transverse -
  • Small Correction Coil: 0.5 A
  • Large Correction Coil: OFF
  • BigBite Current: 518 A
  • BigBite Angle: 82 degrees
  • Halog: click me

May 30, 2009, 00:33

  • Field Strength: 25 Gaus
  • Field Direction: Longitudinal -
  • Pumping Direction: Longitudinal +
  • Small Correction Coil: 0.5 A
  • Large Correction Coil: OFF
  • BigBite Current: 518 A
  • BigBite Angle: 82 degrees
  • Halog: click me

AFP Loss Test

May 19, 2009

  • Field: Longitudinal -
  • Correction Coil: OFF
  • Halog: click me

May 19, 2009

  • Field: Transverse -
  • Correction Coil: OFF
  • Halog: click me

May 21, 2009

  • Field: Transverse +
  • Correction Coil: OFF
  • Halog: click me

Internal Temperature Test

May 19, 2009: Longitudinal

NMR Cross Calibration

May 19, 2009

  • Field: Longitudinal -
  • Correction Coil: OFF
  • Halog