Difference between revisions of "April 14 2011 Meeting Summary"

From Hall A Wiki
Jump to: navigation, search
 
Line 27: Line 27:
  
 
hyao:
 
hyao:
# Try 600,700 Acceptance. See the difference.
+
# Try 600,700 Acceptance. See the difference.<font color=red>---->For right arm, Beam Left Fe, 4 acceptance. 100-200,200-300,300-800,>800. For Beam Right Fe,4 acceptance, 100-200,200-300,300-400,>400. --[[User:Hyao|hyao]] 11:40, 19 April 2011 (UTC)</font>
# For low energy, 300-400 MeV, fix the highest point for xs.
+
# For low energy, 300-400 MeV, fix the highest point for xs.<font color=red>---->Done. --[[User:Hyao|hyao]] 11:40, 19 April 2011 (UTC)</font>
# last three runs for 739 R Fe 60, fix the highest and lowest points.
+
# last three runs for 739 R Fe 60, fix the highest and lowest points.<font color=red>---->Done. --[[User:Hyao|hyao]] 11:40, 19 April 2011 (UTC)</font>
 
# For left arm, at high energy, we might be not necessary to use NaI E/p and Geo Cut.
 
# For left arm, at high energy, we might be not necessary to use NaI E/p and Geo Cut.
 
# For left arm low energy, first get 3 points cs, Then remove NaI E/p and Geo Cut to compare it.
 
# For left arm low energy, first get 3 points cs, Then remove NaI E/p and Geo Cut to compare it.
 
# Continue "To do list" in [[March 31 2011 Meeting Summary]]
 
# Continue "To do list" in [[March 31 2011 Meeting Summary]]

Latest revision as of 11:44, 19 April 2011

Back to CSR Weekly Meeting on 2011


  1. xinhu: [NaI bad block correction check]
  2. hyao: [RHRS New Acceptance and LHRS New Acceptance with New SAMC RZ generator]


xinhu:

  1. Correct most events back. But still not good for Box3.

hyao:

  1. 21612 has problem.
  2. Low energy Cross Section fluctuation < 3~4%.
  3. Left arm cross section is not good.


To do list:

xinhu:

  1. For NaI Eff, make geometry dependent cut efficiency(select pure electron sample) for NaI.
  2. Weight the event by this geo-dep eff when calculating the cross section.
  3. calculate the efficiency for bad block region(select the events in bad block region and add different E/P cuts to see the efficiency changing)
  4. pi rejection for low momentum .
  5. the efficiency for low momentum is a little complex than high momentum due to contamination of electron sample

hyao:

  1. Try 600,700 Acceptance. See the difference.---->For right arm, Beam Left Fe, 4 acceptance. 100-200,200-300,300-800,>800. For Beam Right Fe,4 acceptance, 100-200,200-300,300-400,>400. --hyao 11:40, 19 April 2011 (UTC)
  2. For low energy, 300-400 MeV, fix the highest point for xs.---->Done. --hyao 11:40, 19 April 2011 (UTC)
  3. last three runs for 739 R Fe 60, fix the highest and lowest points.---->Done. --hyao 11:40, 19 April 2011 (UTC)
  4. For left arm, at high energy, we might be not necessary to use NaI E/p and Geo Cut.
  5. For left arm low energy, first get 3 points cs, Then remove NaI E/p and Geo Cut to compare it.
  6. Continue "To do list" in March 31 2011 Meeting Summary