Difference between revisions of "Moller sim dictionary"

From Hall A Wiki
Jump to: navigation, search
(Notes)
(List of variables)
Line 114: Line 114:
 
| O
 
| O
 
| O
 
| O
|
+
| rowspan="4" | Defined in tracking; value comes from hit information
 +
|  rowspan="4" | Momentum direction and energy (MeV) at <b>detector</b>
 
|-
 
|-
 
| px
 
| px
Line 120: Line 121:
 
| O
 
| O
 
| O
 
| O
|  rowspan="3" | Defined in tracking; value comes from hit information
 
|  rowspan="3" | Momenta at <b>detector</b>
 
 
|-
 
|-
 
| py
 
| py

Revision as of 14:23, 9 November 2012

Summary

The ROOT tree variables filled in MollerAnalysis.hh in AddData , which is called from MollerAnalysis.cc.
The values are defined all over the place!
I am trying to catalog exactly where, and decide whether they should be defined differently...

  • x, y, z
  • x0, y0, z0
  • kineE, px, py, pz
  • kineE0, px0, py0, pz0, theta0
  • kineE1, px1, py1, pz1, theta1
  • kineE2, px2, py2, pz2, theta2
  • kineE_org, theta_org
  • type, volume, event, ev_num, hit, track
  • ion, process, creator
  • diffXS, totXS, rate

List of variables

O - used for this generator
X - not used for this generator (seems to always be 0 or -1)

Variable ee ep ine Defined in... Description
x O O O Defined in tracking; value comes from hit information Positions at detector (mm)
y O O O
z O O O
x0 O O O Set in generator; value comes from hit information Positions at vertex (mm)
y0 O O O
z0 O O O
type O O O Defined in tracking; from hit information, but integer value defined in MollerDetectorSD Particle number (e- = 0, e+ = 1, p = 2, p = 3, photon = 4, all others = 5)
volume O O O Defined in tracking; value comes from hit information Volume number; needs work
rate O O O Defined in generator Rate (Hz/μA), needs to be normalized to number thrown
track O O O Defined in tracking; value comes from hit information
event O O O
Variable ee ep ine Defined in... Description
kineE O O O Defined in tracking; value comes from hit information Momentum direction and energy (MeV) at detector
px O O O
py O O O
pz O O O
kineE0 O O O
px0 X X X Defined in generator, MollerAnalysis.cc and MollerDetectorSD?; value comes from generator? Momentum directions at vertex?
py0 X X X
pz0 X X X
kineE1 O O O
px1 O O O
py1 O O O
pz1 O O O
kineE2 O O O
px2 O O O
py2 O O O
pz2 O O O
theta0 X X X
theta1 O O O
theta2 O O O
Variable ee ep ine Defined in... Description
ion X O O Defined in MollerDetectorHit.hh; value comes from MollerDetectorSD - boolean?
ev_num O O O
process X X X
creator O O O
hit O O O
kineE_org O O O
theta_org O O O
diffXS X X X
totXS O O O



Notes

For mollers, the number thrown is 2x the number specified; this will be changed in future versions...



Return to Simulation Projects
Return to MOLLER at 11 GeV E09-005