Difference between revisions of "BigBite/HVControl"

From Hall A Wiki
Jump to: navigation, search
(BigBite High Voltage Control)
(HOWTO save high voltage setting)
Line 30: Line 30:
 
== HV map for BB
 
== HV map for BB
 
* bbps1 S0 to S9 are E and DE BB planes
 
* bbps1 S0 to S9 are E and DE BB planes
* bbps1 S14 to S15 Bigbite MWDC HV
+
**S0 de 1-12 Left  S1 de 13-24 Left S2 de 1-12 Right S3 de 13-24 Right
 +
**S4 E  1-12 Left  S5 E  13-24 Left S6 E  1-12 Right S7 E  13-24 Right
 +
**S8 Bar in front of platform
 +
 
 +
* bbps1 S14 Bigbite MWDC HV
 +
** 0 to 3 front chambers
 +
** 4 to 8 back chambers

Revision as of 01:56, 1 April 2008

BigBite High Voltage Control

HOWTO start the HV Control GUI

  • Log into the adev account on adaql2 (password on sheet next to the WhiteBoard).

For example, in an xterm (logged in as adaq@adaql1):

 [adaq@adaql1 adaq]$ ssh adev@adaql2
  • Run the GUI:
 [adev@adaql2 adev]$ hvgui
  • After some time of reading configuration files and information from the HV Crates (about 30 seconds), the GUI should appear:

Hvgui example.png

HOWTO change high voltage

  • double click the slot you want to change in Target_V column

Hvgui example1.png

  • change the value then hit enter
  • after finish changing please save the setting

HOWTO save high voltage setting

  • click File
  • choose Save Voltage Set

Hvgui example2.png

  • please save the file in the format as you see in the example

BB_month_date_year_time.set

== HV map for BB

  • bbps1 S0 to S9 are E and DE BB planes
    • S0 de 1-12 Left S1 de 13-24 Left S2 de 1-12 Right S3 de 13-24 Right
    • S4 E 1-12 Left S5 E 13-24 Left S6 E 1-12 Right S7 E 13-24 Right
    • S8 Bar in front of platform
  • bbps1 S14 Bigbite MWDC HV
    • 0 to 3 front chambers
    • 4 to 8 back chambers