Difference between revisions of "Spectrometer Optics"
From Hall A Wiki
(→Procedure with Sieve-slit) |
|||
Line 59: | Line 59: | ||
<td>58</td> | <td>58</td> | ||
<td>58</td> | <td>58</td> | ||
+ | </tr> | ||
+ | </table> | ||
+ | |||
+ | ==== Elastic from Hydrogen ==== | ||
+ | |||
+ | Elastic electron-proton measurement. Assuming a 15 cm LH2 target, a spectrometer acceptance of 6 msr and elastic from Eric's rate program to compute the cross-section. Taking data at 7.3 GeV with the given momentum restrictions is time consuming.<br> (Table borrowed from DVCS3 wiki page)<br> | ||
+ | <table border="1" style="width:80%"> | ||
+ | <tr> | ||
+ | <td>E<SUB>beam</SUB> (GeV)</td> | ||
+ | <td>k' (GeV)</td> | ||
+ | <td>θ<SUB>e</SUB> (deg)</td> | ||
+ | <td>Q<SUP>2</SUP> (GeV<SUP>2</SUP>)</td> | ||
+ | <td> Rate [Hz] at 20 μA</td> | ||
+ | <td> minutes for 5.4k events at 20& mu;A</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>7.3</td> | ||
+ | <td>3.2</td> | ||
+ | <td>33.4</td> | ||
+ | <td>7.7</td> | ||
+ | <td>1.5</td> | ||
+ | <td>60</td> | ||
+ | </tr> | ||
+ | <tr> | ||
+ | <td>5.5</td> | ||
+ | <td>3.2</td> | ||
+ | <td>28.7</td> | ||
+ | <td>4.3</td> | ||
+ | <td>15</td> | ||
+ | <td> 6</td> | ||
</tr> | </tr> | ||
</table> | </table> |
Revision as of 13:12, 14 October 2014
Procedure with Sieve-slit
- Time estimate: 1-2 hours
* A Hall A Tech may be required to install the 2-inch lead sieve-slit collimator onto the front face of the HRS. * Take a sieve slit run with the multi-foil carbon target for the inelastic kinematics in the table. * If you need to increase the spectrometer momentum setting, make sure you cycle Q2 and Q3 as per the cycling procedure. * Repeat the above with the beam position shifted so that you see a vertical shift by one row. * Rates assume 5 carbon foils, only 9 out of 25 sieve holes have events (~ 0.146 mSr acceptance), and 9% delta acceptance.
Ebeam [GeV] | P0 [GeV/c] | θe [deg] | Q2 [GeV2] | W [GeV] | Rate [Hz] at 20 μA | minutes for 100k events at 20 μA |
7.3 | 3.200 | 19.0 | 2.5 | 2455 | 15 | 110 |
7.3 | 2.019 | 19.0 | 1.6 | 3030 | 24 | 70 |
Alternative rates with 1-inch tungsten sieve slit: * Assumes that 49 out of the 63 holes are seen (~ 0.52 mSr acceptance); however, the acceptance is reduced by 85%,
since not all foils will see all holes. * Rates assume 5 carbon foils and 9% delta acceptance.
Ebeam [GeV] | P0 [GeV/c] | θe [deg] | Q2 [GeV2] | W [GeV] | Rate [Hz] at 20 μA | minutes for 200k events at 20 μA |
7.3 | 3.056 | 19.0 | 2.4 | 2533 | 58 | 58 |
Elastic from Hydrogen
Elastic electron-proton measurement. Assuming a 15 cm LH2 target, a spectrometer acceptance of 6 msr and elastic from Eric's rate program to compute the cross-section. Taking data at 7.3 GeV with the given momentum restrictions is time consuming.
(Table borrowed from DVCS3 wiki page)
Ebeam (GeV) | k' (GeV) | θe (deg) | Q2 (GeV2) | Rate [Hz] at 20 μA | minutes for 5.4k events at 20& mu;A |
7.3 | 3.2 | 33.4 | 7.7 | 1.5 | 60 |
5.5 | 3.2 | 28.7 | 4.3 | 15 | 6 |