Difference between revisions of "Winter 2016 optic plans"

From Hall A Wiki
Jump to: navigation, search
Line 1: Line 1:
 
Back to [[https://hallaweb.jlab.org/wiki/index.php/Run_Plan_%28DVCS3%29 Winter2016 DVCS run plan]]
 
Back to [[https://hallaweb.jlab.org/wiki/index.php/Run_Plan_%28DVCS3%29 Winter2016 DVCS run plan]]
 +
 
'''If you have questions call Julie Roche, Number is on white board'''<br>
 
'''If you have questions call Julie Roche, Number is on white board'''<br>
 
E<SUB>beam</SUB>= 2.301 GeV<br>
 
E<SUB>beam</SUB>= 2.301 GeV<br>

Revision as of 00:19, 10 February 2016

Back to [Winter2016 DVCS run plan]

If you have questions call Julie Roche, Number is on white board
Ebeam= 2.301 GeV
LHRS θe=16.5 deg
 
LHRS DAQ: S2+Cer, Use LHRNEW for DAQ configuration. See [section 5.2 in DVCS shift howto] for complete procedure!.  

==== Carbon elastic ( no sieve) ====
 
The LHRS goes to a new momentum setting which means Q2 and Q3 need to be cycled.  
LHRS θe=16.5 deg
P0= 2.281 [GeV/c] (super-elastic)
Rate: 1Hz ?? at 20 μ Single Carbon foil or Optics target.

2 hours.


==== Procedure with Sieve-slit (DIS) ====
P0= 1.0 [GeV/c] (DIS)
Q2= 0.19 GeV2
W=1.77 GeV

Target LEFT Q1 Current [A] estimated Rate [Hz] at 20 μA estimated hours at 20 μA actual Rate [Hz] at 20 μA run number # of events in the run
Optics 752 (tuned) 300 1h (or at least 100k events)      
Optics 684 (0.91 detuned) 300 1h (or at least 100k events)      
Optics 624 (0.83 detuned) 300 1h (or at least 100k events)      
Optics 566 (0.74 detuned) 300 1h (or at least 100k events)      
Optics 451 (0.60 detuned) 300 1h (or at least 100k events)      
4 cm Dummy 752 (tuned) 160 45 min (or at least 50k events)      
4 cm Dummy 684 (0.91 detuned) 160 45 min (or at least 50k events)      
4 cm Dummy 624 (0.83 detuned) 160 45 min (or at least 50k events)      
4 cm Dummy 566 (0.74 detuned) 160 45 min (or at least 50k events)      
4 cm Dummy 451 (0.60 detuned) 160 45 min (or at least 50k events)      
C single foil 752 (tuned) 60 20 min (or at least 72k events)      
C single foil 684 (0.91 detuned) 60 20 min (or at least 72k events)      
C single foil 624 (0.83 detuned) 60 20 min (or at least 72k events)      
C single foil 566 (0.74 detuned) 60 20 min (or at least 72k events)      
C single foil 451 (0.60 detuned) 60 20 min (or at least 72k events)      
15 cm LH2 752 (tuned) 780 20 min (or at least 72k events)      
15 cm LH2 684 ( 0.91 detuned) 780 20 min (or at least 72k events)      
15 cm LH2 624 ( 0.83 detuned) 780 20 min (or at least 72k events)      
15 cm LH2 566 (0.74 detuned) 780 20 min (or at least 72k events)      
15 cm LH2 451 (0.60 detuned) 780 20 min (or at least 72k events)      
200 μm tungsten wire 752 (tuned) 26.5 (central hole only) 1h (dictated by Gmp)      




 
 
 

==== Delta Scan with Proton Elastic (sieve) ====
 
 
The LHRS goes to a new higher momentum setting which means Q2 and Q3 need to be cycled.  

LHRS θe=16.5 deg
Rate: 252 kHz at 20 μA (YES 200 KHZ !!!!!) but without the sieve slit. Electron rates only. We are going to take these data at 1 μA. Run duration about 20 minutes each.

</tr>
k' (GeV) LEFT Q1 Current [A] ΔP (%) run number number of trigger
2.02 1517 -4%    
2.02 1380 (0.91 detuned) -4%    
2.02 1259 (0.83 detuned) -4%    
2.02 1123 (0.74 detuned) -4%    
2.02 910 (0.6 detuned) -4%    
2.06 1549 -2%    
2.06 1410 (0.91 detuned) -2%    
2.06 1286 (0.83 detuned) -2%    
2.06 1146 (0.74 detuned) -2%    
2.06 929 (0.60 detuned) -2%    
2.1 1580 0    
2.1 1438 (0.91 detuned) 0    
2.1 1311 (0.83 detuned) 0    
2.1 1169 (0.74 detuned) 0    
2.1 948 (0.6 detuned) 0    
2.14 1612 +2%    
2.14 1438 (0.91 detuned) +2%    
2.14 1311 (0.83 detuned) +2%    
2.14 1169 (0.74 detuned) +2%    
2.14 948 (0.6 detuned) +2%    
2.18 1643 +4%    
2.18 1495 (0.91 detuned) +4%    
2.18 1364 (0.83 detuned) +4%    
2.18 1216 (0.74 detuned) +4%    
2.18 986 (0.6 detuned) +4%