Difference between revisions of "Friday Nov 04, 2016: OWL Shift"
From Hall A Wiki
(New page: ====Shift Duties==== * Take Production data * Log all issues, alarms and questions. * Perform shift checklist. * Log target status twice per shift.) |
|||
Line 1: | Line 1: | ||
+ | Return to [[Daily_Run_Plans|List of Daily Run Plans]] | ||
+ | |||
====Shift Duties==== | ====Shift Duties==== | ||
* Take [[#Production Running|Production data]] | * Take [[#Production Running|Production data]] | ||
Line 4: | Line 6: | ||
* Perform shift checklist. | * Perform shift checklist. | ||
* Log target status twice per shift. | * Log target status twice per shift. | ||
+ | |||
+ | ====Production Running==== | ||
+ | Take 1 hour runs for both Left HRS DAQ and Right HRS DAQ. | ||
+ | Follow Kinematic settings for [[Run_Plan_(DVCS3) | DVCS Kin_60_1]] and [[Parasitic_Production_Run_Plan_R-HRS_48.75_degrees|GMp 4th Pass "Parasitic" Kinematics]], summarized below: | ||
+ | |||
+ | {| | ||
+ | |Beam current | ||
+ | |10 μA | ||
+ | |- | ||
+ | |Beam Energy | ||
+ | |8.5 GeV | ||
+ | |- | ||
+ | |Target | ||
+ | |LH2 (Loop 2) | ||
+ | |- | ||
+ | |Raster | ||
+ | |ON (2x2mm<sup>2</sup>) [MCC units h=2, w=3] | ||
+ | |- | ||
+ | |VDC HV (both arms) | ||
+ | |ON | ||
+ | |- | ||
+ | |DVCS Calo HV | ||
+ | |ON | ||
+ | |} | ||
+ | |||
+ | |||
+ | '''DVCS Kin_60_1''' | ||
+ | {| | ||
+ | |- | ||
+ | |DVCS Calo Angle | ||
+ | |15.89° | ||
+ | |- | ||
+ | |DVCS Calo Distance | ||
+ | | 1.5 m | ||
+ | |- | ||
+ | |LHRS Polarity | ||
+ | |Negative | ||
+ | |- | ||
+ | |LHRS Momentum | ||
+ | |3.594 GeV/c | ||
+ | |- | ||
+ | |LHRS Angle | ||
+ | |24.564° | ||
+ | |- | ||
+ | |LHRS Q1 Current | ||
+ | |749.67 Amps (regulator '''OFF''') | ||
+ | |- | ||
+ | |LHRS DAQ Config | ||
+ | |DVCS | ||
+ | |- | ||
+ | |prescaleL | ||
+ | | PS9=1 (all others zero) | ||
+ | |} | ||
+ | |||
+ | |||
+ | GMp 4th Pass "Parasitic" Kinematics | ||
+ | {| | ||
+ | |- | ||
+ | |RHRS Polarity | ||
+ | |Negative | ||
+ | |- | ||
+ | |RHRS Momentum | ||
+ | |1.804 GeV/c | ||
+ | |- | ||
+ | |RHRS Angle | ||
+ | |53.475° | ||
+ | |- | ||
+ | |RHRS DAQ Config | ||
+ | |RHRSadaq2 | ||
+ | |- | ||
+ | |prescaleR | ||
+ | | PS1=PS2=PS3=1, && PS8=100 (all others zero) | ||
+ | |} | ||
+ | |||
+ | |||
+ | |||
+ | Compton runs | ||
+ | {| | ||
+ | |- | ||
+ | Stop/Start a Compton run every 2 hours - The Compton DAQ is running on the COMPTON computer located in the back room in the Hall A counting house (the room with food) | ||
+ | |} |
Latest revision as of 12:39, 5 November 2016
Return to List of Daily Run Plans
Shift Duties
- Take Production data
- Log all issues, alarms and questions.
- Perform shift checklist.
- Log target status twice per shift.
Production Running
Take 1 hour runs for both Left HRS DAQ and Right HRS DAQ. Follow Kinematic settings for DVCS Kin_60_1 and GMp 4th Pass "Parasitic" Kinematics, summarized below:
Beam current | 10 μA |
Beam Energy | 8.5 GeV |
Target | LH2 (Loop 2) |
Raster | ON (2x2mm2) [MCC units h=2, w=3] |
VDC HV (both arms) | ON |
DVCS Calo HV | ON |
DVCS Kin_60_1
DVCS Calo Angle | 15.89° |
DVCS Calo Distance | 1.5 m |
LHRS Polarity | Negative |
LHRS Momentum | 3.594 GeV/c |
LHRS Angle | 24.564° |
LHRS Q1 Current | 749.67 Amps (regulator OFF) |
LHRS DAQ Config | DVCS |
prescaleL | PS9=1 (all others zero) |
GMp 4th Pass "Parasitic" Kinematics
RHRS Polarity | Negative |
RHRS Momentum | 1.804 GeV/c |
RHRS Angle | 53.475° |
RHRS DAQ Config | RHRSadaq2 |
prescaleR | PS1=PS2=PS3=1, && PS8=100 (all others zero) |
Compton runs