   CREATE TABLE moller_settings(
 
   CREATE TABLE moller_settings(
 
   run INTEGER PRIMARY KEY,          -- run number
 
   run INTEGER PRIMARY KEY,          -- run number
   run_type TEXT DEFAULT '',          -- run type eg. beam_pol
+
   run_type TEXT DEFAULT \'\',          -- run type eg. beam_pol
 
   run_start TEXT DEFAULT '',        -- run start date and time
 
   run_start TEXT DEFAULT '',        -- run start date and time
 
   run_end TEXT DEFAULT '',          -- run end date and time
 
   run_end TEXT DEFAULT '',          -- run end date and time

Revision as of 15:39, 6 August 2019

Here is a link to a database for Moller runs information compiled for PREXII [1]

This is an sqlite3 database. To run it type at the command line

 $sqlite3 MollerRunsDB.sql
 sqlite>

There are 3 tables available:

  • moller_output: information output by the analysis script
  • moller_settings: configuration setting and EPICS readbacks taken at the beginning of each run
  • moller_quality: general information about the type of run and quality

To see what is available type .schema at the sqlite prompt

 sqlite>.schema 
 CREATE TABLE moller_output(
 run INTEGER PRIMARY KEY,           -- run number
 left_singles INTEGER DEFAULT 0,    -- average left detector singles rate (per helicity)
 right_singles INTEGER DEFAULT 0,   -- average right detector singles rate (per helicity)
 coinc INTEGER DEFAULT 0,           -- average coincidence rate (per helicity)
 accid INTEGER DEFAULT 0,           -- average accidental rate (per helicity)
 bcm INTEGER DEFAULT 0,             -- average bcm scalar counts per helicity 
 clock INTEGER DEFAULT 0,           -- average clock counts per helicity
 corrected_asym REAL DEFAULT 0,     -- corrected asymmetry
 corrected_asym_err REAL DEFAULT 0, -- corrected asymmetry error
 pol REAL DEFAULT 0,                -- calculated polarization
 pol_err REAL DEFAULT 0,            -- calculated polarization error
 analyzing_pow REAL DEFAULT 0,      -- effective analyzing power Azz
 target_pol REAL DEFAULT 0,         -- target polarization
 pol_left REAL DEFAULT 0,           -- left detector only asymmetry
 pol_right REAL DEFAULT 0,          -- right detector only asymmetry
 bcm_asym REAL DEFAULT 0,           -- bcm asymmetry
 bcm_asym_err REAL DEFAULT 0        -- bcm asymmetry error
 );
 CREATE TABLE moller_settings(
 run INTEGER PRIMARY KEY,           -- run number
 run_type TEXT DEFAULT \'\',          -- run type eg. beam_pol
 run_start TEXT DEFAULT ,         -- run start date and time
 run_end TEXT DEFAULT ,           -- run end date and time
 run_length REAL DEFAULT 0,         -- run duration (seconds)
 trig_thresh_ch0 REAL DEFAULT 0,    -- ch 0 (left) detector discriminator threshold (mV)
 trig_thresh_ch1 REAL DEFAULT 0,    -- ch 1 (right) detector discriminator threshold (mV)
 ihwp_in INTEGER DEFAULT -1,        -- insertable half-wave plate IN=1; OUT=0
 target INTEGER DEFAULT 0,          -- target 0=not on any target; 1=Cu 11um; 2=Fe 10um; 3=Fe 4um; 4=Fe 1um;
 E_beam REAL DEFAULT 0,             -- Beam energy, MeV Hall A
 E_inj REAL DEFAULT 0,              -- Injector energy, MeV
 E_Slinac REAL DEFAULT 0,           -- South linac energy, MeV
 E_Nlinac REAL DEFAULT 0,           -- North linac energy, MeV
 n_pass REAL DEFAULT 0,             -- Passes Hall A
 bcm_avg REAL DEFAULT 0,            -- Beam Current Average
 unser REAL DEFAULT 0,              -- Current on Unser monitor
 bcm_us REAL DEFAULT 0,             -- Current on Upstream bcm
 bcm_ds REAL DEFAULT 0,             -- Current on Downstream bcm
 inj_bcm_tot REAL DEFAULT 0,        -- Injector Full Current Monitor 02
 inj_bcm_halla REAL DEFAULT 0,      -- Injector Current Monitor Hall A
 bpm01_X REAL DEFAULT 0,            -- Beam Position BPM01  X, mm
 bpm01_Y REAL DEFAULT 0,            -- Beam Position BPM01  Y, mm
 bpm04_X REAL DEFAULT 0,            -- Beam Position BPM04  X, mm
 bpm04_Y REAL DEFAULT 0,            -- Beam Position BPM04  Y, mm
 bpm04a_X REAL DEFAULT 0,           -- Beam Position BPM04A  X, mm
 bpm04a_Y REAL DEFAULT 0,           -- Beam Position BPM04A  Y, mm
 q1_cur REAL DEFAULT 0,             -- Quad Q1 (Amps)
 q2_cur REAL DEFAULT 0,             -- Quad Q2 (Amps)
 q3_cur REAL DEFAULT 0,             -- Quad Q3 (Amps)
 q4_cur REAL DEFAULT 0,             -- Quad Q4 (Amps)
 dip_cur REAL DEFAULT 0,            -- Dipole  (Amps)
 tgt_angle REAL DEFAULT 0,          -- Target Rotary Position(V)
 tgt_angle_deg REAL DEFAULT 0,      -- Rotary Position in deg
 tgt_lin_pos REAL DEFAULT 0,        -- Target Linear Position(V)
 tgt_lin_pos_mm REAL DEFAULT 0,     -- Linear Position in mm
 ihwp TEXT DEFAULT ,              -- Laser 1/2 wave plate
 rhwp REAL DEFAULT 0,               -- Rotating 1/2 wave plate
 vwien_angle REAL DEFAULT 0,        -- VWien filter angle, deg
 sol_phi_fg REAL DEFAULT 0,         -- Solenoids angle, deg
 hwien_angle REAL DEFAULT 0,        -- HWien filter angle, deg
 hel_pattern TEXT DEFAULT ,       -- Helicity mode/pattern
 hel_freq REAL DEFAULT 0,           -- Helicity frequency
 hel_delay TEXT DEFAULT ,         -- Helicity delay
 t_settle REAL DEFAULT 0,           -- MPS signal, usec
 t_stable REAL DEFAULT 0,           -- Helicity window, usec
 bpm02a_X REAL DEFAULT 0,           -- Beam Position BPM02A X, mm
 bpm02a_Y REAL DEFAULT 0,           -- Beam Position BPM02A Y, mm
 mol_mag_cur_set REAL DEFAULT 0,    -- AM430 Current Setpoint (A)
 mol_mag_cur_meas REAL DEFAULT 0,   -- AM430 Measured Current (A)
 mol_mag_v_meas REAL DEFAULT 0,     -- AM430 Measured Voltage (A)
 mol_mag_field_meas REAL DEFAULT 0, -- AM430 Measured Field (T)
 mol_mag_ramp_state REAL DEFAULT 0, -- AMS430 Ramp State
 mol_cooler_temp REAL DEFAULT 0,    -- Cryocooler Temperature (K)
 mol_mag_T2temp REAL DEFAULT 0,     -- Magnet(T2) Temperature(K)
 mol_mag_lead1_temp REAL DEFAULT 0, -- Magnet Lead #1 (T6) Temperature
 mol_mag_lead2_temp REAL DEFAULT 0, -- Magnet Lead #2 (T7) Temperature
 det_hv_ch1 REAL DEFAULT 0,         -- Moller Detector measured HV ch 1
 det_hv_ch2 REAL DEFAULT 0,         -- Moller Detector measured HV ch 2
 det_hv_ch3 REAL DEFAULT 0,         -- Moller Detector measured HV ch 3
 det_hv_ch4 REAL DEFAULT 0,         -- Moller Detector measured HV ch 4
 det_hv_ch5 REAL DEFAULT 0,         -- Moller Detector measured HV ch 5
 det_hv_ch6 REAL DEFAULT 0,         -- Moller Detector measured HV ch 6
 det_hv_ch7 REAL DEFAULT 0,         -- Moller Detector measured HV ch 7
 det_hv_ch8 REAL DEFAULT 0,         -- Moller Detector measured HV ch 8
 det_ap_ch1 REAL DEFAULT 0,         -- Moller Detector measured HV Ap 1
 det_ap_ch2 REAL DEFAULT 0,         -- Moller Detector measured HV Ap 2
 det_ap_ch3 REAL DEFAULT 0,         -- Moller Detector measured HV Ap 3
 det_ap_ch4 REAL DEFAULT 0,         -- Moller Detector measured HV Ap 4
 det_ap_ch5 REAL DEFAULT 0,         -- Moller Detector measured HV Ap 5
 det_ap_ch6 REAL DEFAULT 0,         -- Moller Detector measured HV Ap 6
 det_ap_ch7 REAL DEFAULT 0,         -- Moller Detector measured HV Ap 7
 det_ap_ch8 REAL DEFAULT 0,         -- Moller Detector measured HV Ap 8'
 trig_thresh REAL DEFAULT 0,        -- trigger threshold in mV
 trig_type TEXT DEFAULT ,         -- trigger type: 'left', 'right' or 'coinc'
 mol_pow_sup_cur REAL DEFAULT 0,    -- Moller power supply current (A)
 FOREIGN KEY(run) REFERENCES moller_output(run)
 );
 CREATE TABLE moller_quality(
 run INTEGER PRIMARY KEY,           -- run number
 task TEXT DEFAULT ,              -- 'pol'=polarization, 'qsc'=quad scan, 'dsc'=dipole scan, 'thr'=threshold study, 'trg'=trigger study, 'hv'=high voltage study, 'ped'=pedestal, 'oth'=other
 quality TEXT DEFAULT ,           -- 'good', 'suspect', 'bad'
 comment TEXT DEFAULT ,           -- user input comment about run
 FOREIGN KEY(run) REFERENCES moller_output(run)
 );