Difference between revisions of "DAQ September 25th 2020"

From Hall A Wiki
Jump to: navigation, search
(Created page with "What detectors will be used for GMn and GEn? BigBite (Shower, GRINCH, GEM, Hodoscope) and HCAL Is the hardware fully specified? (Types and numbers crates and modules speci...")
 
 
Line 23: Line 23:
 
TD
 
TD
 
MPD
 
MPD
 +
VETROC
  
 
What is the trigger?  NIM?  Is it designed?
 
What is the trigger?  NIM?  Is it designed?
  
Bigbite Shower analog sum
+
Bigbite Shower analog sum  
 +
GEn RP with coincidence with analog HCAL sum
 +
 
 +
 
  
 
Is hardware for trigger fully specified?
 
Is hardware for trigger fully specified?
Line 40: Line 44:
  
 
In Hall Spring 2021
 
In Hall Spring 2021
 +
 +
  
 
What can not be tested without beam?
 
What can not be tested without beam?
 +
 +
Background in chamber (X-ray test at UVA )
  
  
Line 51: Line 59:
 
UVA GEM
 
UVA GEM
 
HCAL
 
HCAL
 +
CDet
  
 
Yes
 
Yes
Line 60: Line 69:
  
 
Is all the hardware in hand?  Do all the cables exist?
 
Is all the hardware in hand?  Do all the cables exist?
 +
Yes besides
 +
Cables Shower to FADC
  
  
Line 71: Line 82:
 
When will it be returned?
 
When will it be returned?
  
 
+
VXS crate at UMAss, Hanjie will use to setup GEM readout for BigBite
  
 
What are the typical and maximum data rates?
 
What are the typical and maximum data rates?
 +
 +
 +
  
 
Is networking and computing sufficient?
 
Is networking and computing sufficient?
Line 82: Line 96:
 
quality checks?
 
quality checks?
  
Yes
+
Yes,
  
 
What work is needed from FEDAQ group?  Does work have sufficient priority?
 
What work is needed from FEDAQ group?  Does work have sufficient priority?
  
 
GEM firmware, highest priority
 
GEM firmware, highest priority

Latest revision as of 11:46, 25 September 2020

What detectors will be used for GMn and GEn?

BigBite (Shower, GRINCH, GEM, Hodoscope) and HCAL

Is the hardware fully specified? (Types and numbers crates and modules specified.) Are there any design choices not made?

Yes

Is there firmware that needs to be developed? When will it be ready? Can it be tested without beam?

GEM readout firmware

What DAQ modules are used?

FADC F1 V1190 V792 TI TS TD MPD VETROC

What is the trigger? NIM? Is it designed?

Bigbite Shower analog sum GEn RP with coincidence with analog HCAL sum


Is hardware for trigger fully specified?

Yes

What version of CODA will be used?

CODA3

When will full DAQ system be assembled? (Will this be in hall or elsewhere?)

In Hall Spring 2021


What can not be tested without beam?

Background in chamber (X-ray test at UVA )


What detector test DAQs exist? Are they all used for the full DAQ?

GRINCH BB Shower INFN GEM UVA GEM HCAL CDet

Yes

What is the status of GEM readout?

Optical readout being tested, new MPD firmware in development for zero supression, common noise supression and packing in 32 bit words


Is all the hardware in hand? Do all the cables exist? Yes besides Cables Shower to FADC


Is any borrowed hardware used and if so has possession of that hardware been taken?

Need to get 10 FADCs from electronics group and 2 SD

Is any needed hardware currently loaned out for non SBS/Bigbite uses? When will it be returned?

VXS crate at UMAss, Hanjie will use to setup GEM readout for BigBite

What are the typical and maximum data rates?



Is networking and computing sufficient?

Yes

Will analysis software be ready enough for at least online data quality checks?

Yes,

What work is needed from FEDAQ group? Does work have sufficient priority?

GEM firmware, highest priority