Difference between revisions of "Cosmics in TEDf"
From Hall A Wiki
(Created page with "Currently running with cosmics in TEDf (Feb 2021). Set up: * 89 bars * 2 CAEN v1190 TDCs (recording time information from all 180 channels) * 2 v792 QDCs (recording charge inf...") |
|||
Line 3: | Line 3: | ||
* 2 CAEN v1190 TDCs (recording time information from all 180 channels) | * 2 CAEN v1190 TDCs (recording time information from all 180 channels) | ||
* 2 v792 QDCs (recording charge information from subsets of 64 channels at a time) | * 2 v792 QDCs (recording charge information from subsets of 64 channels at a time) | ||
− | * 12 NINO cads | + | * 12 NINO cads operating with AGILENT PSU and operating with internal threshold set by potentiometer on cards |
− | * HV supplied by CAEN SY1527N main frame equipped with A1932A HV modules. | + | * HV supplied by CAEN SY1527N main frame equipped with A1932A HV modules (4 necessary, 4 spare). |
− | Details on ROC etc to be added here | + | Details on ROC and coda3 setup etc to be added here: |
+ | * | ||
− | Details of | + | Details of running coda and analysis on tedbbdaq machine: |
− | * account is bbhodo | + | * account is bbhodo |
+ | * To run coda: | ||
+ | * To run analysis scripts: | ||
+ | * |
Revision as of 18:25, 8 February 2021
Currently running with cosmics in TEDf (Feb 2021). Set up:
- 89 bars
- 2 CAEN v1190 TDCs (recording time information from all 180 channels)
- 2 v792 QDCs (recording charge information from subsets of 64 channels at a time)
- 12 NINO cads operating with AGILENT PSU and operating with internal threshold set by potentiometer on cards
- HV supplied by CAEN SY1527N main frame equipped with A1932A HV modules (4 necessary, 4 spare).
Details on ROC and coda3 setup etc to be added here:
Details of running coda and analysis on tedbbdaq machine:
- account is bbhodo
- To run coda:
- To run analysis scripts: