Difference between revisions of "Helmholtz Coils Settings for Different Magnet Configurations"
From Hall A Wiki
Line 1: | Line 1: | ||
+ | << [https://hallaweb.jlab.org/wiki/index.php/Pol_He-3_Target_Information_GEn Back] | ||
+ | |||
[[File:HoldingFieldControl.png|500px|right|thumb|TO can change the settings within the red circle. Theta should stay at 90, but you will change phi based on the first table on this page. Once you've entered the correct numbers, click the blue button that says "Start Rotation" and wait for the field to adjust.]] | [[File:HoldingFieldControl.png|500px|right|thumb|TO can change the settings within the red circle. Theta should stay at 90, but you will change phi based on the first table on this page. Once you've entered the correct numbers, click the blue button that says "Start Rotation" and wait for the field to adjust.]] | ||
Revision as of 03:53, 15 October 2022
<< Back
Target operator should make sure that the holding field is set properly for each magnet configuration. The last column shows what settings need to be manually changed.
BigBite | SuperBigBite | Bx | By | HH Coils Settings |
---|---|---|---|---|
OFF | OFF | 23.072 | 12.042 | 26.03G at 62.44o |
ON | ON | 17.242 | 13.582 | 25.00G at 51.77o |
ON | OFF | 21.212 | 13.172 | 24.97G at 58.16o |
OFF | ON | 16.302 | 13.292 | 21.03G at 49.50o |
Extra information for fields:
Magnet Configuration | Bx | By |
---|---|---|
Background | -1.4 | +0.42 |
SBS and BB and Background | +4.43 | -1.12 |
SBS and Background | +3.97 | -0.41 |
SBS | +5.37 | -0.83 |
BB | +0.46 | -0.71 |