Difference between revisions of "Helmholtz Coils Settings for Different Magnet Configurations"

From Hall A Wiki
Jump to: navigation, search
Line 6: Line 6:
  
 
{| class="wikitable" style="margin:auto"
 
{| class="wikitable" style="margin:auto"
! BigBite !! SuperBigBite !! B<sub>x</sub> !! B<sub>y</sub> !! HH Coils Settings
+
! BigBite !! SuperBigBite !! B<sub>x</sub> !! B<sub>z</sub> !! HH Coils Settings
 
|-
 
|-
 
| OFF || OFF || 23.072 || 12.042 || 26.03G at 62.44<sup>o</sup>
 
| OFF || OFF || 23.072 || 12.042 || 26.03G at 62.44<sup>o</sup>
Line 22: Line 22:
  
 
{| class="wikitable" style="margin:auto"
 
{| class="wikitable" style="margin:auto"
! Magnet Configuration !! B<sub>x</sub> !! B<sub>y</sub>
+
! Magnet Configuration !! B<sub>x</sub> !! B<sub>z</sub>
 
|-
 
|-
 
| Background || -1.4 || +0.42
 
| Background || -1.4 || +0.42

Revision as of 07:34, 15 October 2022

<< Back

TO can change the settings within the red circle. Theta should stay at 90, but you will change phi based on the first table on this page. Once you've entered the correct numbers, click the blue button that says "Start Rotation" and wait for the field to adjust.

Target operator should make sure that the holding field is set properly for each magnet configuration. The last column shows what settings need to be manually changed.

BigBite SuperBigBite Bx Bz HH Coils Settings
OFF OFF 23.072 12.042 26.03G at 62.44o
ON ON 17.242 13.582 25.00G at 51.77o *
ON OFF 22.612 12.752 20.70G at 60.58o
OFF ON 17.702 12.889 22.14G at 49.50o
*Settings used during compass measurements.

Extra information for fields:

Magnet Configuration Bx Bz
Background -1.4 +0.42
SBS and BB and Background +4.43 -1.12
SBS and Background +3.97 -0.41
SBS +5.37 -0.83
BB +0.46 -0.71