Difference between revisions of "Measurements"

From Hall A Wiki
Jump to: navigation, search
(Recent polarization measurements)
(Recent polarization measurements)
Line 75: Line 75:
 
After doing an NMR sweep, record the date, time, and polarization percentage. Link to a log entry in which you include a screenshot of the NMR Field Sweep Control Program.
 
After doing an NMR sweep, record the date, time, and polarization percentage. Link to a log entry in which you include a screenshot of the NMR Field Sweep Control Program.
 
* date, time, polarization% : link to log entry
 
* date, time, polarization% : link to log entry
 +
* 11/11/2022 00:58 27.6% : [https://logbooks.jlab.org/entry/4080494]
 +
* 11/11/2022 04:18 33.0% : [https://logbooks.jlab.org/entry/4080593]
 +
* 11/11/2022 06:18 34.4% : [https://logbooks.jlab.org/entry/4080670]
 +
* 11/11/2022 08:48 35.3% : [https://logbooks.jlab.org/entry/4080756]
 +
* 11/11/2022 12:38 37.8% : [https://logbooks.jlab.org/entry/4080941]
 
* 11/11/2022 15:53 41.4% : [https://logbooks.jlab.org/entry/4081069]
 
* 11/11/2022 15:53 41.4% : [https://logbooks.jlab.org/entry/4081069]

Revision as of 17:17, 11 November 2022

<< Back

Target Polarization Angle Conventions

Be VERY clear here about the convention (beam-right/left/up/downstream) vs 0, 90, 180, 270)
for each run period.  More notes and references to log entries are better.

Taking an NMR Measurement

  1. Make sure that the holding field settings are correct for whatever magnetic field settings you're working with.
    1. Note that if you have to change the holding field, you will then need to restart the NMR GUI once the holding field is in its new configuration.
    2. This can be done by pressing the red "stop" button in the top left hand corner and then the "run" button.
  2. Call MCC to mask the beam so that you can move the target to the "pickup coils" position.
  3. Make sure that the NMR GUI settings are correct. The high field should be 34G and all of the sensitivities should be 100.
  4. In the white box on the bottom left hand side of the NMR GUI you can write a comment with convection and B field settings.
  5. Press the green "Start" button.

Polarization Calibration Data

ADD LIST OF CALIBRATION RUNS HERE
AND A TABLE OF RELEVANT CALIBRATION CONSTANTS TO USE FOR WHAT RUNS
Cell Calibration
Type
SHMS Angle
/degree
SHMS Momentum
/GeV
Field Direction
/degree
Calibration Results Status Oven Temperature
/°C
Log#
Hunter EPR-NMR 11 7.5 90 5.24 %/mV Done 200 3839939
Hunter EPR-NMR 18 5.6 90 undone 205
Hunter EPR-NMR 11 7.5 270 undone 208
Hunter AFP Loss 14.5 6.4 90 1.25%/Sweep Done 200 3840618, 3840143, 3840618

Recent polarization measurements

After doing an NMR sweep, record the date, time, and polarization percentage. Link to a log entry in which you include a screenshot of the NMR Field Sweep Control Program.

  • date, time, polarization% : link to log entry
  • 11/11/2022 00:58 27.6% : [1]
  • 11/11/2022 04:18 33.0% : [2]
  • 11/11/2022 06:18 34.4% : [3]
  • 11/11/2022 08:48 35.3% : [4]
  • 11/11/2022 12:38 37.8% : [5]
  • 11/11/2022 15:53 41.4% : [6]